MR of focal liver lesions: Comparison of breath-hold and non-breath-hold hybrid RARE and conventional spin-echo T2-weighted pulse sequences

被引:17
作者
Carpenter, KD [1 ]
Macaulay, SE [1 ]
Schulte, SJ [1 ]
Obregon, RG [1 ]
Nelson, RC [1 ]
Simon, HE [1 ]
Schmiedl, UP [1 ]
机构
[1] VET ADM MED CTR,DEPT RADIOL,SEATTLE,WA 98108
来源
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING | 1996年 / 6卷 / 04期
关键词
liver neoplasms; magnetic resonance imaging; comparative studies;
D O I
10.1002/jmri.1880060407
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To compare liver lesion detection rates, tissue signal and noise data, and qualitative parameters for breath-hold (BH) and non-breath-hold (NBH) hybrid rapid acquisition with relaxation enhancement (RARE) and conventional spin-echo (CSE) T2-weighted (CSE-T2) MR sequences, 20 patients were imaged using all three sequences. Lesion detection rates were 73.5% for the CSE-T2 sequence and 81.1% and 88.6% for the BH-RARE and NBH-RARE sequences, respectively (P = .027). Mean lesion-to-liver signal-difference-to-noise ratio for the NBH-RARE sequence was 14.0 +/- 11.5, significantly greater than 9.8 +/- 7.8 obtained for the BH-RARE sequence (P = .050) and 9.0 +/- 6.2 obtained for the CSE-T2 sequence (P = 0.15). The NBH-RARE sequence demonstrated fewer artifacts and greater overall image quality compared to the CSE-T2 sequence. The NBH-RARE sequence is a useful alternative to the CSE-T2 sequence providing a higher mean lesion-to-liver signal-difference-to-noise ratio and lesion detection rate and better overall image quality.
引用
收藏
页码:596 / 602
页数:7
相关论文
共 20 条
[1]   T2-WEIGHTED MR-IMAGING OF THE ABDOMEN - FAST SPIN-ECHO VS CONVENTIONAL SPIN-ECHO SEQUENCES [J].
CATASCA, JV ;
MIROWITZ, SA .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1994, 162 (01) :61-67
[2]   SIGNAL-TO-NOISE AND CONTRAST IN FAST SPIN-ECHO (FSE) AND INVERSION RECOVERY FSE IMAGING [J].
CONSTABLE, RT ;
SMITH, RC ;
GORE, JC .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1992, 16 (01) :41-47
[3]   FACTORS INFLUENCING CONTRAST IN FAST SPIN-ECHO MR IMAGING [J].
CONSTABLE, RT ;
ANDERSON, AW ;
ZHONG, J ;
GORE, JC .
MAGNETIC RESONANCE IMAGING, 1992, 10 (04) :497-511
[4]   CONTRAST OPTIMIZATION FOR THE DETECTION OF FOCAL HEPATIC-LESIONS BY MR IMAGING AT 1.5-T [J].
FOLEY, WD ;
KNEELAND, JB ;
CATES, JD ;
KELLMAN, GM ;
LAWSON, TL ;
MIDDLETON, WD ;
HENDRICK, RE .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1987, 149 (06) :1155-1160
[5]   RARE IMAGING - A FAST IMAGING METHOD FOR CLINICAL MR [J].
HENNIG, J ;
NAUERTH, A ;
FRIEDBURG, H .
MAGNETIC RESONANCE IN MEDICINE, 1986, 3 (06) :823-833
[6]   DIFFERENTIATION BETWEEN SMALL HEPATIC HEMANGIOMAS AND METASTASES ON MR IMAGES - IMPORTANCE OF SIZE-SPECIFIC QUANTITATIVE CRITERIA [J].
ITOH, K ;
SAINI, S ;
HAHN, PF ;
IMAM, N ;
FERRUCCI, JT .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1990, 155 (01) :61-66
[7]   MEASURING SIGNAL-TO-NOISE RATIOS IN MR IMAGING [J].
KAUFMAN, L ;
KRAMER, DM ;
CROOKS, LE ;
ORTENDAHL, DA .
RADIOLOGY, 1989, 173 (01) :265-267
[8]  
Listerud J, 1992, Magn Reson Q, V8, P199
[9]   ABDOMINAL MR IMAGING - COMPARISON OF T2-WEIGHTED FAST AND CONVENTIONAL SPIN-ECHO, AND CONTRAST-ENHANCED FAST MULTIPLANAR SPOILED GRADIENT-RECALLED IMAGING [J].
LOW, RN ;
FRANCIS, IR ;
SIGETI, JS ;
FOO, TKF .
RADIOLOGY, 1993, 186 (03) :803-811
[10]   COMPARING THE FAISE METHOD WITH CONVENTIONAL DUAL-ECHO SEQUENCES [J].
MELKI, PS ;
MULKERN, RV ;
PANYCH, LP ;
JOLESZ, FA .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1991, 1 (03) :319-326