Radiation-induced temporary hair loss as a radiation damage only occurring in patients who had the combination of MDCT and DSA

被引:104
作者
Imanishi, Y
Fukui, A
Niimi, H
Itoh, D
Nozaki, K
Nakaji, S
Ishizuka, K
Tabata, H
Furuya, Y
Uzura, M
Takahama, H
Hashizume, S
Arima, S
Nakajima, Y
机构
[1] St Marianna Univ, Sch Med, Dept Radiol, Miyamae Ku, Kawasaki, Kanagawa 2168511, Japan
[2] St Marianna Univ, Sch Med, Dept Emergency, Miyamae Ku, Kawasaki, Kanagawa 2168511, Japan
[3] St Marianna Univ, Sch Med, Dept Radiog, Miyamae Ku, Kawasaki, Kanagawa 2168511, Japan
关键词
hair loss; MDCT; perfusion study by MDCT; complication of radiation; skin; effects of irradiation on;
D O I
10.1007/s00330-004-2459-1
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
As imaging technologies become increasingly advanced, it is possible to obtain detailed morphological information as well as functional imaging data. In some imaging technologies, the radiation dose increases with the ability to obtain better images or more detailed information. We encountered three cases of temporary bandage-shaped hair loss, which was caused by perfusion studies of the head by multi-detector row computed tomography (MDCT) for evaluation of cerebral blood flow in patients with vascular disorders. In all three patients with temporary hair loss, two angiographies of the head had been performed in the period of serial CT examinations. This suggested the possibility that radiation exposure from angiography performed in serial examinations, combined with the perfusion studies of the head with MDCT, played an important role in this temporary, bandage-shaped hair loss. Radiologists should be aware that a cumulative or multiplier effect of radiation exposure from multiple diagnostic techniques may result in hair loss and other types of radiation complications.
引用
收藏
页码:41 / 46
页数:6
相关论文
共 13 条
[1]  
[Anonymous], 1984, ICRP PUBL
[2]  
D'Incan M, 2002, ANN DERMATOL VENER, V129, P703
[3]   Radiotherapy and radiosurgical management of brain metastases. [J].
Flickinger J.C. .
Current Oncology Reports, 2001, 3 (6) :484-489
[4]   Non-traumatic neurological emergencies: imaging of cerebral ischemia [J].
Grunwald, I ;
Reith, W .
EUROPEAN RADIOLOGY, 2002, 12 (07) :1632-1647
[5]   Radiation exposure during cardiac CT: Effective doses at multi-detector row CT and electron-beam CT [J].
Hunold, P ;
Vogt, FM ;
Schmermund, A ;
Debatin, JF ;
Kerkhoff, G ;
Budde, T ;
Erbel, R ;
Ewen, K ;
Barkhausen, J .
RADIOLOGY, 2003, 226 (01) :145-152
[6]   Multislice CT: update on radiation and screening [J].
Kalra, MK ;
Maher, MM ;
Saini, S .
EUROPEAN RADIOLOGY, 2003, 13 (Suppl 5) :M129-M133
[7]  
Mettler Fred A. Jr., 2000, Journal of Radiological Protection, V20, P353, DOI 10.1088/0952-4746/20/4/301
[8]   Acute cerebral stroke imaging and brain perfusion with the use of high-concentration contrast media [J].
Miles, KA .
EUROPEAN RADIOLOGY, 2003, 13 (Suppl 5) :M117-M120
[9]   Absorbed dose and deterministic effects to patients from interventional neuroradiology [J].
Mooney, RB ;
McKinstry, CS ;
Kamel, HAM .
BRITISH JOURNAL OF RADIOLOGY, 2000, 73 (871) :745-751
[10]  
Task Group on Accident Prevention and Safety in Radiation Therapy, 2000, Ann ICRP, V30, P7