The susceptibility of prosthetic biomaterials to infection

被引:78
作者
Carbonell, AM
Matthews, BD
Dréau, D
Foster, M
Austin, CE
Kercher, KW
Sing, RF
Heniford, BT
机构
[1] Carolinas Med Ctr, Dept Gen Surg, Carolinas Laparoscop & Adv Surg Program, Charlotte, NC 28203 USA
[2] Univ N Carolina, Dept Biol, Charlotte, NC 28223 USA
来源
SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES | 2005年 / 19卷 / 03期
关键词
prosthetics; biomaterials; mesh implantation; bacterial infection; silver/chlorhexidine; polypropylene; Marlex; SepraMesh; surgisis; composix; expanded polytetrafluoroethylene (ePTFE); DualMesh AlloDerm;
D O I
10.1007/s00464-004-8810-4
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background: Despite the use of a sterile technique and the administration of prophylactic antibiotics during surgical procedures, mesh infection continues to complicate the use of biomaterials. The purpose of this study was to compare the susceptibility to infection of prosthetic biomaterials in a live-animal model. Methods: The following seven prosthetic mesh biomaterials were used in this study. Expanded polytetrafluoroethylene (ePTFE) with silver/chlorhexidine (DM+), ePTFE (DM), porcine intestinal submucosa (S), polypropylene (M), ePTFE/polypropylene (X), hyaluronate/carboxymethylcellulose/polypropylene (SM), and human acellular dermal matrix (A). Lewis rats (n = 108) underwent creation of a single ventral hernia; 105 of them were repaired with a different mesh (2-cm(2) piece). Twelve pieces of each mesh were inoculated at the time of hernia repair with 10(8) Staphylococcus aureus (n = 84). Three pieces of each mesh were placed without bacterial inoculation (n = 21). In three animals, no mesh was placed; instead, the peritoneum of the hernia defect was inoculated (n = 3). After 5 days, the animals were killed and the mesh was explanted (peritoneum for the nonmesh control). The mesh was vortex-washed and incubated in tryptic soy broth. Bacterial counts were determined using serial dilutions and spot plates and quantified in colony-forming units (CFU) per square centimeter of mesh present in the vortex wash fluid (wash count) and the soy broth (broth count). Data are presented Lis the mean log(10), with analysis of variance (ANOVA) and Tukey's test used to determine significance (p < 0.05). Results: The DM + material had no detectable live bacteria in the wash or broth counts in 10 of 12 tested samples (p = 0.05). Of the samples that showed bacterial growth, the peritoneum control group had a lower wash count than A (p = 0.05) and the lowest broth Count of all the materials except for DM + (p = 0.05). In addition, SM had a significantly lower wash count than A (p = 0.05), with no broth count difference. In regard to wash and broth counts, DM, M, X, SM, S, and A were no different (p = NS). Conclusions: The DM+ material was the least susceptible to infection. Impregnation with silver/chlorhexidine killed the inoculated bacteria, preventing their proliferation on the mesh surface. Other than DM +, native peritoneal tissue appears to be the least susceptible to infection. Silver/chlorhexidine appears to be an effective bactericidal agent for use with mesh biomaterials.
引用
收藏
页码:430 / 435
页数:6
相关论文
共 35 条
[1]  
Abramov D, 1996, EUR J SURG, V162, P945
[2]   PREVENTION OF CATHETER-RELATED INFECTIONS BY ANTISEPTIC BONDING [J].
BACH, A ;
BOHRER, H ;
MOTSCH, J ;
MARTIN, E ;
GEISS, HK ;
SONNTAG, HG .
JOURNAL OF SURGICAL RESEARCH, 1993, 55 (06) :640-646
[3]   Effect of relaparotomy through previously integrated polypropylene and polytetrafluoroethylene experimental implants in the abdominal wall [J].
Bellón, JM ;
Contreras, LA ;
Buján, J ;
Pascual, G ;
Carrera-San Martín, A .
JOURNAL OF THE AMERICAN COLLEGE OF SURGEONS, 1999, 188 (05) :466-472
[4]   In vitro interaction of bacteria with polypropylene/ePTFE prostheses [J].
Bellón, JM ;
G-Honduvilla, N ;
Jurado, F ;
G-Carranza, A ;
Buján, J .
BIOMATERIALS, 2001, 22 (14) :2021-2024
[5]  
BLEICHRODT RP, 1993, SURG GYNECOL OBSTET, V176, P18
[6]   COMPARISON OF PROSTHETIC MATERIALS FOR ABDOMINAL-WALL RECONSTRUCTION IN THE PRESENCE OF CONTAMINATION AND INFECTION [J].
BROWN, GL ;
RICHARDSON, JD ;
MALANGONI, MA ;
TOBIN, GR ;
ACKERMAN, D ;
POLK, HC .
ANNALS OF SURGERY, 1985, 201 (06) :705-711
[7]  
CARBONELL AM, 2003, 2 INT HERN C LOND EN
[8]  
COBB WS, 2004, ANN M AM HERN SOC OR
[9]   A comparison of two antimicrobial-impregnated central venous catheters [J].
Darouiche, RO ;
Raad, II ;
Heard, SO ;
Thornby, JI ;
Wenker, OC ;
Gabrielli, A ;
Berg, J ;
Khardori, N ;
Hanna, H ;
Hachem, R ;
Harris, RL ;
Mayhall, G .
NEW ENGLAND JOURNAL OF MEDICINE, 1999, 340 (01) :1-8
[10]  
Darouiche RO, 1998, J HEART VALVE DIS, V7, P639