Ex vivo evaluation of a Taylor-Couette flow, immobilized heparinase I device for clinical application

被引:27
作者
Ameer, GA
Barabino, G
Sasisekharan, R
Harmon, W
Cooney, CL
Langer, R
机构
[1] MIT, Dept Chem Engn, Cambridge, MA 02139 USA
[2] MIT, Div Bioengn & Environm Hlth, Cambridge, MA 02139 USA
[3] MIT, Ctr Biotechnol Proc Engn, Cambridge, MA 02139 USA
[4] MIT, Ctr Biomed Engn, Cambridge, MA 02139 USA
[5] Northeastern Univ, Dept Chem Engn, Boston, MA 02115 USA
[6] Childrens Hosp, Dept Nephrol, Boston, MA 02115 USA
关键词
D O I
10.1073/pnas.96.5.2350
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Efficient and safe heparin anticoagulation has remained a problem for continuous renal replacement therapies and intermittent hemodialysis for patients with acute renal failure, To make heparin therapy safer for the patient with acute renal failure at high risk of bleeding, we have proposed regional heparinization of the circuit via an immobilized heparinase I filter, This study tested a device based on Taylor-Couette flow and simultaneous separation/reaction for efficacy and safety of heparin removal in a sheep model, Heparinase I was immobilized onto agarose beads via cyanogen bromide activation. The de,ice, referred to as a vortex flow plasmapheretic reactor, consisted of two concentric cylinders, a priming volume of 45 ml, a microporous membrane for plasma separation, and an outer compartment where the immobilized heparinase I was fluidized separately from the blood cells, Manual white cell and platelet counts, hematocrit, total protein, and fibrinogen assays were performed. Heparin levels were indirectly measured via whole-blood recalcification times (WBRTs). The vortex flow plasmapheretic reactor maintained significantly higher heparin levels in the extracorporeal circuit than in the sheep (device inlet WBRTs were 1.5 times the device outlet WBRTs) with no hemolysis, The reactor treatment did not effect any physiologically significant changes in complete blood cell counts, platelets, and protein levels for up to 2 hr of operation. Furthermore, gross necropsy and histopathology did not show any significant abnormalities in the kidney, liver, heart, brain, and spleen.
引用
收藏
页码:2350 / 2355
页数:6
相关论文
共 18 条
[1]  
AMEER GA, 1999, IN PRESS BIOTECHNOL
[2]  
AMEER GA, 1999, IN PRESS AICHE J
[3]  
BELLOMO R, 1993, KIDNEY INT, V43, pS237
[4]   EXTRACORPOREAL ENZYMATIC HEPARIN REMOVAL - USE IN A SHEEP DIALYSIS MODEL [J].
BERNSTEIN, H ;
YANG, VC ;
LUND, D ;
RANDHAWA, M ;
HARMON, W ;
LANGER, R .
KIDNEY INTERNATIONAL, 1987, 32 (04) :452-463
[5]  
BROYER M, 1986, NEPHROL DIAL TRANSPL, V1, P1
[6]  
BURHOP KE, 1993, J LAB CLIN MED, V121, P276
[7]  
FREED LE, 1988, THESIS MIT CAMBRIDGE
[8]  
GAJEWSKI J, 1971, AM J VET RES, V32, P405
[9]  
HECKER JF, 1993, SHEEP EXPT ANIMAL
[10]   HEMODIALYZER PERFORMANCE - BIOLOGICAL INDEXES [J].
HOLMES, CJ .