Developing an animal model of massive ulcer bleeding for assessing endoscopic hemostatic devices

被引:19
作者
Hu, B
Chung, SCS [1 ]
Sun, LCL
Lau, JYW
Kawashima, K
Yamamoto, T
Cotton, PB
Gostout, CJ
Hawes, RH
Kalloo, AN
Kantsevoy, SV
Pasricha, PJ
机构
[1] Chinese Univ Hong Kong, Prince Wales Hosp, Endoscopy Ctr, Shatin, Hong Kong, Peoples R China
[2] Olympus Corp, R&D Dept, Tokyo, Japan
关键词
n;
D O I
10.1055/s-2005-870226
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background: Existing animal models of ulcerative bleeding are not suitable for endoscopic investigation. We describe a new porcine model of massive arterial bleeding in the stomach and its use for assessing a novel endoscopic suturing device. Methods: Two animal models were investigated. In model 1, the short gastric artery (mean diameter 2 mm) was divided near its gastric end. A mucosal defect was created near the greater curve and the divided artery was brought into the lumen of the stomach through a submucosal tunnel. An inflatable plastic cuff was placed around the base of the artery. Cuff deflation led to massive bleeding. In model 2, the short gastric artery was carefully exposed along a segment of 2 cm on the side facing the stomach. It was then anchored to a small gastrostomy made at the posterior wall near the vessel. At endoscopy an ulcer-like lesion could be seen with a pulsatile vessel at the base and brisk bleeding could be started by cutting a hole in the artery using endoscissors. The pigs were heparinized by an intravenous bolus of 110-300 units per kilogram, in both models. A prototype suturing device, the Eagle Claw, was inserted using a gastroscope and the curved needle was driven around the bleeding artery. Extracorporeal knotting or intracorporeal ligation was done endoscopically. Results: Pulsatile arterial bleeding was successfully created in four pigs using model 1, and in another four pigs using model 2. Model 2 was more reproducible and less time-consuming to create. Endoscopic suturing controlled arterial bleeding in five out of eight pigs with a single stitch and in another three pigs with an additional stitch. Conclusion: This animal model provides reproducible massive hemorrhage suitable for endoscopic studies. Control of gastric bleeding from large arteries by endoscopic suturing is possible.
引用
收藏
页码:847 / 851
页数:5
相关论文
共 19 条
[1]   ANIMAL TESTING OF ENDOSCOPIC HEMOSTASIS WITH LASERS AND OTHER DEVICES [J].
AUTH, DC .
ENDOSCOPY, 1986, 18 :36-39
[2]  
BRODIE DA, 1962, GASTROENTEROLOGY, V43, P107
[3]   ENDOSCOPIC ASSESSMENT OF MUCOSAL HEMODYNAMIC-CHANGES IN A CANINE MODEL OF GASTRIC-ULCER [J].
CHUNG, SCS ;
SUNG, JY ;
SUEN, MWM ;
LEUNG, JWC ;
LEUNG, FW .
GASTROINTESTINAL ENDOSCOPY, 1991, 37 (03) :310-314
[4]   LASER-INDUCED HEMOSTASIS IN CANINE STOMACH - USE OF A FLEXIBLE FIBEROPTIC DELIVERY SYSTEM [J].
DWYER, RM ;
HAVERBACK, BJ ;
BASS, M ;
CHERLOW, J .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1975, 231 (05) :486-489
[5]   Gastroprotective effects of honey and glucose-fructose-sucrose-maltose mixture against ethanol-, indomethacin-, and acidified aspirin-induced lesions in the rat [J].
Gharzouli, K ;
Amira, S ;
Gharzouli, A ;
Khennouf, S .
EXPERIMENTAL AND TOXICOLOGIC PATHOLOGY, 2002, 54 (03) :217-221
[6]  
HATAFUKU T, 1970, Surgical Forum (Chicago), V21, P314
[7]  
Hu B, 2004, GASTROINTEST ENDOSC, V59, pAB114
[8]  
HU B, 2003, ENDOSC, V57, pAB84
[9]   EXPERIMENTAL COMPARISON OF ENDOSCOPIC YTTRIUM-ALUMINUM-GARNET LASER, ELECTROSURGERY, AND HEATER PROBE FOR CANINE GUT ARTERIAL COAGULATION - IMPORTANCE OF COMPRESSION AND AVOIDANCE OF EROSION [J].
JOHNSTON, JH ;
JENSEN, DM ;
AUTH, D .
GASTROENTEROLOGY, 1987, 92 (05) :1101-1108
[10]   The antioxidative and antihistaminic properties of quercetin in ethanol-induced gastric lesions [J].
Kahraman, A ;
Erkasap, N ;
Köken, T ;
Serteser, M ;
Aktepe, F ;
Erkasap, S .
TOXICOLOGY, 2003, 183 (1-3) :133-142