Proposed solution to the FROC problem and an invitation to collaborate

被引:7
作者
Chakraborty, DP [1 ]
机构
[1] Univ Pittsburgh, Dept Radiol, Pittsburgh, PA 15213 USA
来源
MEDICAL IMAGING 2003: IMAGE PERCEPTION, OBSERVER PERFORMANCE, AND TECHNOLOGY ASSESSMENT | 2003年 / 5034卷
关键词
FROC; ROC; statistical model; localization; detection; methodology; maximum likelihood;
D O I
10.1117/12.480068
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
There is a need to develop observer performance methodologies that are not restricted to binary tasks, as is the widely used Receiver Operating Characteristic (ROC) method. Clinical tasks involving lesion localization do not fit the ROC paradigm. Alternative approaches namely Free-response ROC (FROC) and Localization ROC (LROC), have their own limitations. They neglect intra-image correlations, with consequent questionable statistical validity, the image scoring criterion is arbitrary and affects the results, and they do not account for the two sub-tasks, namely detection and localization, inherent to these experiments. The purpose of this work is to propose a new FROC model that deals with these issues, to propose a maximum likelihood method of estimating the model parameters, and to invite collaboration by others in implementing the solution. As proof-of-principle that the model yields reasonable FROC data, the model was used to generate simulated FROC data, which was analyzed by conventional FROC analysis. Measures of detection and localization performance are proposed that will allow FROC performance to, be interpreted quantitatively, and observer performance experiments to be conducted with greater statistical power.
引用
收藏
页码:204 / 212
页数:9
相关论文
共 11 条
[1]   Statistical power in observer-performance studies: Comparison of the receiver operating characteristic and free-response methods in tasks involving localization [J].
Chakraborty, D .
ACADEMIC RADIOLOGY, 2002, 9 (02) :147-156
[2]   MAXIMUM-LIKELIHOOD ANALYSIS OF FREE-RESPONSE RECEIVER OPERATING CHARACTERISTIC (FROC) DATA [J].
CHAKRABORTY, DP .
MEDICAL PHYSICS, 1989, 16 (04) :561-568
[3]   FREE-RESPONSE METHODOLOGY - ALTERNATE ANALYSIS AND A NEW OBSERVER-PERFORMANCE EXPERIMENT [J].
CHAKRABORTY, DP ;
WINTER, LHL .
RADIOLOGY, 1990, 174 (03) :873-881
[4]  
MCLACHLAN GJ, 1997, EM ALGORITHGM EXTENS
[6]  
METZ CE, 1986, INVEST RADIOL, V21, P720, DOI 10.1097/00004424-198609000-00009
[7]  
METZ CE, 1996, DIGITAL MAMMOGRAPHY
[8]  
Obuchowski NA, 2000, ACAD RADIOL, V7, P516, DOI 10.1016/S1076-6332(00)80324-4
[9]   Bootstrap estimation of diagnostic accuracy with patient-clustered data [J].
Rutter, CM .
ACADEMIC RADIOLOGY, 2000, 7 (06) :413-419
[10]   Using localization data from image interpretations to improve estimates of performance accuracy [J].
Swensson, RG .
MEDICAL DECISION MAKING, 2000, 20 (02) :170-185