Design of dynamic voltage restorer with disturbance-filtering enhancement

被引:30
作者
Huang, CJ [1 ]
Huang, SJ
Pai, FS
机构
[1] Kun Shan Univ Technol, Dept Elect Engn, Tainan 710, Taiwan
[2] Natl Cheng Kung Univ, Dept Elect Engn, Tainan 70101, Taiwan
关键词
dynamic voltage restorer; voltage sag;
D O I
10.1109/TPEL.2003.816192
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this paper, a new approach for the design of dynamic voltage restorer is proposed. By installing the filtering scheme at utility side and load side, the designated dynamic voltage restorer not only effectively compensates' the voltage disturbances, but also helps ensure the supplying power quality. To validate the effectiveness of the method, several disturbance scenarios including voltage sag, oscillatory transients and power surges Were examined in the simulation study. This is further supported through the hardware realization of the proposed design, where experimental results obtained under load change and voltage distortion scenarios were both investigated. Test results revealed that the proposed, method is able to withstand possible disturbances at a faster. dynamic response, thereby consolidating the feasibility and practicality of the approach for the applications considered.
引用
收藏
页码:1202 / 1210
页数:9
相关论文
共 15 条
[1]   Analysis and design of a multiple feedback loop control strategy for single-phase voltage-source UPS inverters [J].
AbdelRahim, NM ;
Quaicoe, JE .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 1996, 11 (04) :532-541
[2]  
Arrillaga J., 2000, Power System Quality Assessment
[3]   Dynamic sag correctors: Cost-effective industrial power line conditioning [J].
Brumsickle, WE ;
Schneider, RS ;
Luckjiff, GA ;
Divan, DM ;
McGranaghan, MF .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2001, 37 (01) :212-217
[4]   Analysis and design of a series-connected PWM voltage regulator for single-phase AC sources [J].
Campos, A ;
Joos, G ;
Ziogas, PD ;
Lindsay, JF .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1996, 32 (06) :1285-1292
[5]   Electric-power-quality improvement using parallel active-power conditioners [J].
Huang, SJ ;
Wu, JC ;
Jou, HL .
IEE PROCEEDINGS-GENERATION TRANSMISSION AND DISTRIBUTION, 1998, 145 (05) :597-603
[6]   A control algorithm for three-phase three-wired active power filters under nonideal mains voltages [J].
Huang, SJ ;
Wu, JC .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 1999, 14 (04) :753-760
[7]   Step-up/down AC voltage regulator using transformer with tap changer and PWM AC chopper [J].
Jang, DH ;
Choe, GH .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 1998, 45 (06) :905-911
[8]  
JOOS G, 1999, P IEEE INT S IND EL, P515
[9]   A novel on-line UPS with universal filtering capabilities [J].
Kamran, F ;
Habetler, TG .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 1998, 13 (03) :410-418
[10]   Design considerations on the line-side filter used in the dynamic voltage restorer [J].
Li, BH ;
Choi, SS ;
Vilathgamuwa, DM .
IEE PROCEEDINGS-GENERATION TRANSMISSION AND DISTRIBUTION, 2001, 148 (01) :1-7