Comparability of RP-HPLC retention indices of drugs in three databases

被引:15
作者
Bogusz, M
Hill, DW
Rehorek, A
机构
[1] UNIV CONNECTICUT,MICROCHEM LAB,STORRS,CT 06269
[2] E MERCK AG,CHROMATOG DIV,D-64271 DARMSTADT,GERMANY
关键词
D O I
10.1080/10826079608006319
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Three databases of HPLC retention indices in the 1-nitroalkane scale were recently established (IFM = Institute of Forensic Medicine, MCL = Microchemistry Laboratory, MTSS = Merck Tox Screening System). In two of them (IFM and MTSS) virtually identical chromatographic conditions were applied but different RP-columns. In the third system (MCL) a different column and different elution conditions were used. Among a total of 1149 drugs examined in all three labs, 258 drugs were common for LFM and MTSS, 179 were common for MCL and MTSS, 162 were common for IFM and MCL, and 135 drugs were common for all three databases.
引用
收藏
页码:1291 / 1316
页数:26
相关论文
共 33 条
[1]   ACID-BASE EQUILIBRIA AND ASSAY OF BENZODIAZEPINES IN ACETONITRILE MEDIUM [J].
BARBOSA, J ;
SANZNEBOT, V .
TALANTA, 1989, 36 (08) :837-842
[2]   SILICA - BACKBONE MATERIAL OF LIQUID-CHROMATOGRAPHIC COLUMN PACKINGS [J].
BERTHOD, A .
JOURNAL OF CHROMATOGRAPHY, 1991, 549 (1-2) :1-28
[3]   CORRECTION OF RETENTION INDEX VALUES IN HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY AS A TOOL FOR COMPARISON OF RESULTS OBTAINED WITH DIFFERENT OCTADECYL SILICA PHASES [J].
BOGUSZ, M .
JOURNAL OF CHROMATOGRAPHY, 1987, 387 :404-409
[4]   REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC DATABASE OF RETENTION INDEXES AND UV SPECTRA OF TOXICOLOGICALLY RELEVANT SUBSTANCES AND ITS INTERLABORATORY USE [J].
BOGUSZ, M ;
ERKENS, M .
JOURNAL OF CHROMATOGRAPHY A, 1994, 674 (1-2) :97-126
[5]   INFLUENCE OF ELUTION CONDITIONS ON HPLC RETENTION INDEX VALUES OF SELECTED ACIDIC AND BASIC DRUGS MEASURED IN THE 1-NITROALKANE SCALE [J].
BOGUSZ, M .
JOURNAL OF ANALYTICAL TOXICOLOGY, 1991, 15 (04) :174-178
[6]  
BOGUSZ M, 1992, J LIQ CHROMATOGR, V15, P127
[7]   STANDARDIZED HPLC/DAD SYSTEM, BASED ON RETENTION INDEXES AND SPECTRAL LIBRARY, APPLICABLE FOR SYSTEMATIC TOXICOLOGICAL SCREENING [J].
BOGUSZ, M ;
WU, M .
JOURNAL OF ANALYTICAL TOXICOLOGY, 1991, 15 (04) :188-197
[8]   INFLUENCE OF BIOLOGICAL MATRIX ON CHROMATOGRAPHIC BEHAVIOR AND DETECTION OF SELECTED ACIDIC, NEUTRAL, AND BASIC DRUGS EXAMINED BY MEANS OF A STANDARDIZED HPLC DAD SYSTEM [J].
BOGUSZ, M ;
ERKENS, M .
JOURNAL OF ANALYTICAL TOXICOLOGY, 1995, 19 (01) :49-55
[9]  
Bogusz M., 1995, RETENTION SELECTIVIT, P171
[10]  
BOGUSZ M, 1988, J CHROMATOGR, V388, P37