Evaluation of a dual-beam near-infrared spectrometer based on acousto-optic tunable filters

被引:18
作者
Guchardi, R [1 ]
Pasquini, C [1 ]
机构
[1] Univ Estadual Campinas, Inst Quim, BR-13083970 Campinas, SP, Brazil
关键词
near-infrared spectroscopy; dual-beam spectrometer; acousto-optic tunable filter; water in ethanol;
D O I
10.1366/0003702011951966
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A dual-beam near-infrared (NIR) spectrometer was constructed and evaluated, The instrument was designed to work with the two monochromatic beams produced by each one of the two acoustooptic tunable filters (AOTFs) evaluated, capable of scanning the wavelength range 800-1600 or 1500-2400 nm. Two temperature-controlled, cooled InAs detectors were employed for comparison of the two monochromatic beams produced by the AOTF. Data were obtained in a controlled ambient temperature, (25 +/- 1) degreesC, and were compared for their intensity and wavelength coincidence for each of the 300 values of radio frequency (85-160 and 56-92 MHz) applied to the AOTF. The results show that the two beams present good concordance as a function of the wavelength (mean Delta lambda < 0.30 inn for both AOTFs investigated, The normalized intensities of the two beams were quite different, and their ratio values (0.9 to 1.2) depend on the wavelength. inversion of intensities was observed in the present case and can be attributed to the unmatched position of the two detectors and to the difference in responsivity. On the other hand, the use of the two beams revealed that it can provide a robust way to correct for light-source intensity fluctuation as high as 10%. The mean standard deviation for long-term operation and for a zero absorbance baseline was reduced three times when the dual-beam instrument was employed. The instrument has also been evaluated for determination of water in fuel ethanol, The results for water content demonstrate the good analytical performance of the spectrometer with a relative error of 0.07 and 0.03% (w/w) for water determination in the ranges 0.20-10.0 and 0.20-3.00%, respectively.
引用
收藏
页码:454 / 457
页数:4
相关论文
共 14 条
  • [1] BAROCSI A, 1993, OPT ENG, V32, P2564
  • [2] *CAMO SA, 1998, US MAN UNSCR 7 5
  • [3] CIURCZAK EW, 1992, CHEMTECH JUN, P374
  • [4] DRENNEN JK, 1991, CRIT REV ANAL CHEM, V22, P147
  • [5] FATELEY WG, 1997, P 8 C NIR SPECTR ESS
  • [6] DIRECT DETERMINATION OF ETHANOL IN ALL TYPES OF ALCOHOLIC BEVERAGES BY NEAR-INFRARED DERIVATIVE SPECTROMETRY
    GALLIGNANI, M
    GARRIGUES, S
    DELAGUARDIA, M
    [J]. ANALYST, 1993, 118 (09) : 1167 - 1173
  • [7] FLOW-INJECTION DETERMINATION OF WATER IN ORGANIC-SOLVENTS BY NEAR-INFRARED SPECTROMETRY
    GARRIGUES, S
    GALLIGNANI, M
    DELAGUARDIA, M
    [J]. ANALYTICA CHIMICA ACTA, 1993, 281 (02) : 259 - 264
  • [8] *NIST, 2000, WEB PAG AT SPECTR DA
  • [9] PRUFER H, 1995, ANALUSIS, V23, pM14
  • [10] ROTOLO P, 1979, CEREAL FOOD WORLD, V24, P94