Liquid chromatography under critical and limiting conditions: A survey of experimental systems for synthetic polymers

被引:114
作者
Macko, T [1 ]
Hunkeler, D [1 ]
机构
[1] Swiss Fed Inst Technol, Lab Polyelectrolytes & BioMacromol, Ecublens, CH-1015 Lausanne, Switzerland
来源
LIQUID CHROMATOGRAPHY FTIR MICROSPECTROSCOPY MICROWAVE ASSISTED SYNTHESIS | 2003年 / 163卷
关键词
liquid chromatography; critical conditions; limiting conditions; synthetic polymers;
D O I
10.1007/b11053
中图分类号
O63 [高分子化学(高聚物)];
学科分类号
070305 ; 080501 ; 081704 ;
摘要
At the interface between the entropic size exclusion separation and the enthalpy-dominated liquid adsorption chromatography it is possible, experimentally, to identify conditions where polymer samples elute independent of their molar mass. These "critical conditions" function according to theory by compensating the entropy and enthalpy of the separation. For a series of common and specialty polymers, the mobile phase compositions and temperature which provide the molar mass independent elution behavior, for a given stationary phase, have been extracted from literature and summarized herein. This collection may help to select, or forecast, suitable LC systems, when an application of liquid chromatography under critical conditions for a polymer is required. Correlations between properties of solvents, sorbents and polymers, such as solubility parameters, eluotropic strength and Mark-Houwink constants have been extracted from the collected data. Specifically, solubity parameters of critical mobile phases corresponding to a pair polymer-sorbent are in a majority of cases very similar. The elution strength of the first component of a critical binary eluent correlates linearly with the volume percent of the second component, especially, when an identical silica gel is applied. However, the critical conditions are independent of the thermodynamic quality of the solvent. Under limiting conditions, the mobile phase maybe even a precipitant or a strong adsorption promoting liquid for an injected polymer. Possibilities for increase of the upper molar mass separation limit are outlined and influence of sample solvent on elution behavior is described. Applications of liquid chromatography under conditions of enthalpy-entropy compensation for separation of homo- and copolymers are also, briefly, summarized.
引用
收藏
页码:61 / 136
页数:76
相关论文
共 185 条
[1]   Two-dimensional chromatography of complex polymers Part 1. Analysis of a graft copolymer by two-dimensional chromatography with on-line FTIR detection [J].
Adrian, J ;
Esser, E ;
Hellmann, G ;
Pasch, H .
POLYMER, 2000, 41 (07) :2439-2449
[2]  
Adrian J, 1999, ANGEW MAKROMOL CHEM, V267, P82
[3]  
Adrian J, 1999, ANGEW MAKROMOL CHEM, V267, P73
[4]  
ADRIAN J, 1998, LC GC EUR, V11, P32
[5]   ORTHOGONAL CHROMATOGRAPHY - CHROMATOGRAPHIC CROSS-FRACTIONATION OF POLYMERS [J].
BALKE, ST .
SEPARATION AND PURIFICATION METHODS, 1982, 11 (01) :1-28
[6]  
BALKE ST, 1987, DETECTION DATA ANAL, P59
[7]  
BALKE ST, 1983, POLYM CHARACTERIZATI, P281
[8]  
BANEKII BG, 1996, STRATEGIES SIZE EXCL, P274
[9]  
Baran K, 1999, MACROMOL CHEM PHYSIC, V200, P2074, DOI 10.1002/(SICI)1521-3935(19990901)200:9<2074::AID-MACP2074>3.3.CO
[10]  
2-3