Fabrication of calcium fluoride capillary electrophoresis microdevices for on-chip infrared detection

被引:39
作者
Pan, T [1 ]
Kelly, RT [1 ]
Asplund, MC [1 ]
Woolley, AT [1 ]
机构
[1] Brigham Young Univ, Dept Chem & Biochem, Provo, UT 84602 USA
关键词
detection; electrophoresis; chip technology; instrumentation; calcium fluoride; amino acids;
D O I
10.1016/S0021-9673(03)01300-1
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In this paper, we demonstrate microfluidic capillary electrophoresis (CE) devices made in CaF2, for optical detection in a broad spectral range. We have desiged methods for micromachining and enclosing capillaries in CaF2. The utility of these microdevices has been shown through CE analysis of fluorescently labeled amino acids. We have also performed infrared spectroscopy for analyte identification in microfluidic CaF2 channels. These CaF2 microdevices open the door to microchip separations with optical detection in the ultraviolet, visible, and infrared spectral regions. (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:231 / 235
页数:5
相关论文
共 20 条
[1]   Micro total analysis systems. 2. Analytical standard operations and applications [J].
Auroux, PA ;
Iossifidis, D ;
Reyes, DR ;
Manz, A .
ANALYTICAL CHEMISTRY, 2002, 74 (12) :2637-2652
[2]   Self-organization of large-area periodic nanowire arrays by glancing incidence ion bombardment of CaF2(111) surfaces [J].
Batzill, M ;
Bardou, F ;
Snowdon, KJ .
JOURNAL OF VACUUM SCIENCE & TECHNOLOGY A, 2001, 19 (04) :1829-1834
[3]   Polymer microfluidic devices [J].
Becker, H ;
Locascio, LE .
TALANTA, 2002, 56 (02) :267-287
[4]   Electroosmotic flow in composite microchannels and implications in microcapillary electrophoresis systems [J].
Bianchi, F ;
Wagner, F ;
Hoffmann, P ;
Girault, HH .
ANALYTICAL CHEMISTRY, 2001, 73 (04) :829-836
[5]   Plastic advances microfluidic devices. [J].
Boone, T ;
Fan, ZH ;
Hooper, H ;
Ricco, A ;
Tan, HD ;
Williams, S .
ANALYTICAL CHEMISTRY, 2002, 74 (03) :78A-86A
[6]   TOWARDS MINIATURIZED ELECTROPHORESIS AND CHEMICAL-ANALYSIS SYSTEMS ON SILICON - AN ALTERNATIVE TO CHEMICAL SENSORS [J].
HARRISON, DJ ;
GLAVINA, PG ;
MANZ, A .
SENSORS AND ACTUATORS B-CHEMICAL, 1993, 10 (02) :107-116
[7]   CAPILLARY ELECTROPHORESIS AND SAMPLE INJECTION SYSTEMS INTEGRATED ON A PLANAR GLASS CHIP [J].
HARRISON, DJ ;
MANZ, A ;
FAN, ZH ;
LUDI, H ;
WIDMER, HM .
ANALYTICAL CHEMISTRY, 1992, 64 (17) :1926-1932
[8]   FUSED QUARTZ SUBSTRATES FOR MICROCHIP ELECTROPHORESIS [J].
JACOBSON, SC ;
MOORE, AW ;
RAMSEY, JM .
ANALYTICAL CHEMISTRY, 1995, 67 (13) :2059-2063
[9]   EFFECTS OF INJECTION SCHEMES AND COLUMN GEOMETRY ON THE PERFORMANCE OF MICROCHIP ELECTROPHORESIS DEVICES [J].
JACOBSON, SC ;
HERGENRODER, R ;
KOUTNY, LB ;
WARMACK, RJ ;
RAMSEY, JM .
ANALYTICAL CHEMISTRY, 1994, 66 (07) :1107-1113
[10]   Thermal bonding of polymeric capillary electrophoresis microdevices in water [J].
Kelly, RT ;
Woolley, AT .
ANALYTICAL CHEMISTRY, 2003, 75 (08) :1941-1945