Current status and future prospects of parenteral insulin regimens, strategies and delivery systems for diabetes treatment

被引:43
作者
Jeandidier, N [1 ]
Boivin, S [1 ]
机构
[1] Hop Univ Strasbourg, F-67091 Strasbourg, France
关键词
artificial pancreas; diabetes mellitus; glucose sensors; insulin pumps; intensive insulin therapy; parenteral insulin regimens; self glucose monitoring;
D O I
10.1016/S0169-409X(98)00072-6
中图分类号
R9 [药学];
学科分类号
1007 [药学];
摘要
A strong relationship between long term metabolic control and low frequency of chronic diabetes complications was shown in the Diabetes Control Complication Trial (DCCT). However, the subcutaneous intensive insulin therapy required to achieve the glycemic goals defined by the DCCT led to an unacceptable frequency of severe hypoglycemia and a significant weight gain. This limits the benefits of this therapy and excludes groups of patients such as young children, the elderly or hypoglycemia prone patients. The intensive therapy and self blood glucose monitoring (SMBG) necessary to limit hypoglycemia represent a heavy burden for the patients and their family. Improvements in parenteral insulin therapy are possible by either modifying subcutaneous insulin characteristics (analogs, adjunction of peptides such as amylin, GLP1, IGF1), or by developing better routes of administration and making SMBG easier; which is a key to intensive insulin therapy success. The ultimate goal remains the development of an automated, glucose controlled device. (C) 1999 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:179 / 198
页数:20
相关论文
共 113 条
[1]
VETERANS AFFAIRS COOPERATIVE STUDY ON GLYCEMIC CONTROL AND COMPLICATIONS IN TYPE-II DIABETES (VA CSDM) - RESULTS OF THE FEASIBILITY TRIAL [J].
ABRAIRA, C ;
COLWELL, JA ;
NUTTALL, FQ ;
SAWIN, CT ;
NAGEL, NJ ;
COMSTOCK, JP ;
EMANUELE, NV ;
LEVIN, SR ;
HENDERSON, W ;
LEE, HS .
DIABETES CARE, 1995, 18 (08) :1113-1123
[2]
INSULIN DOSAGE ADJUSTMENT USING MANUAL METHODS AND COMPUTER ALGORITHMS - A COMPARATIVE-STUDY [J].
ALBISSER, AM ;
SCHIFFRIN, A ;
SCHULZ, M ;
TIRAN, J ;
LEIBEL, BS .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1986, 24 (06) :577-584
[3]
*AM DIAB ASS, 1998, DIABETES CARE S1, V21, pS88
[4]
INFLUENCE OF INSULIN PEN INJECTION FREQUENCY ON QUALITY-OF-LIFE [J].
ANDERSSON, PO ;
WIKBY, A ;
HORNQUIST, JO .
DIABETES CARE, 1990, 13 (11) :1135-1136
[5]
Non-invasive glucose monitoring [J].
Arnold, MA .
CURRENT OPINION IN BIOTECHNOLOGY, 1996, 7 (01) :46-49
[6]
INTRAPERITONEAL INSULIN THERAPY CORRECTS ABNORMALITIES IN CHOLESTERYL ESTER TRANSFER AND LIPOPROTEIN-LIPASE ACTIVITIES IN INSULIN-DEPENDENT DIABETES-MELLITUS [J].
BAGDADE, JD ;
DUNN, FL ;
ECKEL, RH ;
RITTER, MC .
ARTERIOSCLEROSIS AND THROMBOSIS, 1994, 14 (12) :1933-1939
[7]
Are presently available insulin analogues clinically beneficial? [J].
Berger, M ;
Heinemann, L .
DIABETOLOGIA, 1997, 40 (Suppl 2) :S91-S96
[8]
Reduction in severe hypoglycemia with long-term continuous subcutaneous insulin infusion in type I diabetes [J].
Bode, BW ;
Steed, RD ;
Davidson, PC .
DIABETES CARE, 1996, 19 (04) :324-327
[9]
BOIVIN S, 1998, 17 WORKSH EASD STUD
[10]
BOIVIN S, 1997, INTRAVENOUS INSULIN