Decision trees using apparent resistance to detect impending loss of synchronism

被引:46
作者
Rovnyak, SM [1 ]
Taylor, CW
Sheng, Y
机构
[1] Louisiana Tech Univ, Ruston, LA 71272 USA
[2] Bonneville Power Adm, Vancouver, WA 98666 USA
基金
美国国家科学基金会; 美国国家卫生研究院;
关键词
adaptive control; pattern recognition; power system transient stability; relay control systems;
D O I
10.1109/61.891496
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper shows how to use decision trees for predicting loss of synchronism on an AC intertie using apparent resistance along with its rate of change measured near the electrical center of the intertie, Operation is response based like most controlled separation schemes including the actual R-Rdot relay which was installed on the Pacific AC Intertie (PACI), Response based control by a decision tree (DT) is achieved by turning every time sample from every simulation into an input-output pair for the DT training set. Different misclassification costs are specified for false trips versus failures to trip in order to adjust their relative frequencies of occurrence. Pattern recognition approaches to discrete event control can potentially be trained and tested for this and for other applications in large-scale simulation.
引用
收藏
页码:1157 / 1162
页数:6
相关论文
共 17 条
[1]  
Breiman L., 1984, BIOMETRICS, DOI DOI 10.2307/2530946
[2]   An adaptive out-of-step relay [J].
Centeno, V ;
Phadke, AG ;
Edris, A ;
Benton, J ;
Gaudi, M ;
Michel, G .
IEEE TRANSACTIONS ON POWER DELIVERY, 1997, 12 (01) :61-71
[3]  
*EPRI, 1997, TR107908 EPRI
[4]   EXPERIENCE WITH THE R-RDOT OUT-OF-STEP RELAY [J].
HANER, JM ;
LAUGHLIN, TD ;
TAYLOR, CW .
IEEE TRANSACTIONS ON POWER DELIVERY, 1986, 1 (02) :35-39
[5]   BC HYDROS ONLINE TRANSIENT STABILITY ASSESSMENT (TSA) MODEL DEVELOPMENT, ANALYSIS, AND POST-PROCESSING [J].
MANSOUR, Y ;
VAAHEDI, E ;
CHANG, AY ;
CORNS, BR ;
GARRETT, BW ;
DEMAREE, K ;
ATHAY, T ;
CHEUNG, K .
IEEE TRANSACTIONS ON POWER SYSTEMS, 1995, 10 (01) :241-253
[6]   STABILIZING CONTROL-SYSTEM PREVENTING LOSS OF SYNCHRONISM FROM EXTENSION AND ITS ACTUAL OPERATING EXPERIENCE [J].
MATSUZAWA, K ;
YANAGIHASHI, K ;
TSUKITA, JK ;
SATO, M ;
NAKAMURA, T ;
TAKEUCHI, A .
IEEE TRANSACTIONS ON POWER SYSTEMS, 1995, 10 (03) :1606-1613
[7]   A new method for detecting loss of synchronism using power and current measured on a line [J].
Minakawa, T ;
Sato, M ;
Ichikawa, Y ;
Ishihara, Y .
IEEE TRANSACTIONS ON POWER DELIVERY, 1999, 14 (01) :68-73
[8]   Development of transient stability control system (TSC system) based on on-line stability calculation - Discussion [J].
Miller, NW ;
Larsen, E ;
Ihara, S .
IEEE TRANSACTIONS ON POWER SYSTEMS, 1996, 11 (03) :1471-1471
[9]   DECISION TREES FOR REAL-TIME TRANSIENT STABILITY PREDICTION [J].
ROVNYAK, S ;
KRETSINGER, S ;
THORP, J ;
BROWN, D .
IEEE TRANSACTIONS ON POWER SYSTEMS, 1994, 9 (03) :1417-1426
[10]   Performance index and classifier approaches to real-time, discrete-event control [J].
Rovnyak, SM ;
Taylor, CW ;
Thorp, JS .
CONTROL ENGINEERING PRACTICE, 1997, 5 (01) :91-99