Oxygen transport through methacrylate-based hydrogels with potential biological capability

被引:19
作者
Compan, V
SanRoman, J
Riande, E
Sorensen, TS
Levenfeld, B
Andrio, A
机构
[1] CSIC, INST CIENCIA & TECNOL POLIMEROS, E-28006 MADRID, SPAIN
[2] MODELLING & THERMODYNAM, DK-2720 VANLOSE, DENMARK
关键词
hydrogels; contact lenses; oxygen transport; permeability; pharmacological capability;
D O I
10.1016/0142-9612(96)84945-3
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The permeability to oxygen of hydrogels prepared from copolymers of 2-hydroxymethyl methacrylate and p-methacryloxyl-oxyacetanilide have been studied by using an oxygen electrode in combination with a permeometer. The transmissibility Dk/L and the permeability Dk (where D, k and L are, respectively, the diffusion coefficient, the Henry constant and the thickness of the hydrogel) are measured by a combination of steady state and transitory state measurements. Both transport coefficients increase with the water content, which in turn depends on the copolymer composition. The values of these quantities tend toward a limiting value for water-saturated hydrogels. The ratio of the characteristic volume for diffusion of the oxygen molecule to the free volume of water per mole water is found to be in the vicinity of 0.10, and this value increases slightly as the fraction of the hydrophilic comonomer in the hydrogel increases. A detailed comparison of the biogels studied with six commercial contact lenses has also been performed. (C) 1996 Elsevier Science Limited.
引用
收藏
页码:1243 / 1249
页数:7
相关论文
共 33 条
[1]   RAPID DETERMINATION OF OXYGEN PERMEABILITY OF POLYMER MEMBRANES [J].
AIBA, S ;
OHASHI, M ;
HUANG, SY .
INDUSTRIAL & ENGINEERING CHEMISTRY FUNDAMENTALS, 1968, 7 (03) :497-&
[2]  
CHIEN YW, 1982, NOVEL DRUG DELIVERY, P26
[3]   TRUE AND APPARENT OXYGEN PERMEABILITIES OF CONTACT-LENSES [J].
COMPAN, V ;
GARRIDO, J ;
MANZANARES, JA ;
ANDRES, J ;
ESTEVE, JS ;
LOPEZ, ML .
OPTOMETRY AND VISION SCIENCE, 1992, 69 (09) :685-690
[4]   DETERMINATION OF THE GLASS-TRANSITION TEMPERATURE OF POLY(CYCLOHEXYL ACRYLATE) FROM OXYGEN PERMEABILITY MEASUREMENTS [J].
COMPAN, V ;
LOPEZ, ML ;
MONFERRER, L ;
GARRIDO, J ;
RIANDE, E ;
SANROMAN, J .
POLYMER, 1993, 34 (14) :2971-2974
[5]   Permeability of co-extruded linear low-density polyethylene films to oxygen and carbon dioxide as determined by electrochemical techniques [J].
Compan, V ;
Ribes, A ;
DiazCalleja, R ;
Riande, E .
POLYMER, 1996, 37 (11) :2243-2250
[6]   MECHANICAL RELAXATIONS AND DIFFUSIONAL CHARACTERISTICS OF COEXTRUDED FILMS PREPARED FROM COPOLYMERS OF ETHYLENE-1-OCTENE [J].
COMPAN, V ;
RIBES, A ;
DIAZCALLEJA, R ;
RIANDE, E .
POLYMER, 1995, 36 (02) :323-330
[7]  
COMPAN V, 1993, POLYMER, V34, P3483
[8]  
CRANK J, 1975, MATH DIFFUSION, P45
[9]  
Dumitriu Severian, 1994, P435
[10]  
DUNAN R, 1989, CONTROLLED RELEASE T, P24