Clinical evaluation of the Mycobacteria growth indicator tube (MGIT) compared with radiometric (Bactec) and solid media for isolation of Mycobacterium species

被引:35
作者
Chew, WK [1 ]
Lasaitis, RM [1 ]
Schio, FA [1 ]
Gilbert, GL [1 ]
机构
[1] Westmead Hosp, Inst Clin Pathol & Med Res, Ctr Infect Dis & Microbiol Lab Serv, Mycobacterium Reference Lab, Sydney, NSW 2145, Australia
关键词
D O I
10.1099/00222615-47-9-821
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
The aim of this study was to evaluate the clinical use of a new culture system for the isolation of mycobacteria. Routine clinical specimens were cultured in the Mycobacteria Growth Indicator Tube, the radiometric Bactec 460 TB system and on Lowenstein Jensen (LJ) medium to compare recovery rates and times for detection of mycobacteria and contamination rates. MGIT was tested for its ability to support the growth of a wide range of mycobacterial species. Acid-fast bacilli (AFB) were detected on direct smears of 76 of 603 clinical specimens and mycobacteria were isolated by at least one method from 109 specimens; 93% of these were detected in the MGIT, 95% in the Bactec 460 TB system and 87% on LJ medium. The MGIT, Bactec and LJ media detected 92%, 97% and 95%, respectively, of 61 M. tuberculosis isolates and 94%, 94% and 77% of the 48 isolates belonging to the M. avium complex (TI;IAC). The mean detection times in MGIT, Bactec and LJ media for,II. tuberculosis were 22, 14 and 27 days respectively, and for MAC were 14, 12, and 29 days, respectively. Growth of M. tuberculosis was detected in Bactec, within 4 weeks, in 93% of the 61 culture-positive specimens, compared with only 61% in MGIT and 66% on LJ. The number of MAC detected within 4 weeks was similar in Bactec and MGIT, but less in LJ medium. Differences in sensitivity and time to detection of growth between media were greater for specimens in which AFB were not detected on direct smear than those on which AFB were seen. Contamination rates were similar in the three systems (3-4%). MGIT supported the growth of all 28 Mycobacterium spp. inoculated. MGIT has significant safety advantages and is less labour intensive than other methods, but the time to detection of M. tuberculosis, especially in smear-negative specimens, was longer in MGIT than in Bactec.
引用
收藏
页码:821 / 827
页数:7
相关论文
共 13 条
[1]   COMPARISON OF MB-CHECK, BACTEC, AND EGG-BASED MEDIA FOR RECOVERY OF MYCOBACTERIA [J].
ABE, C ;
HOSOJIMA, S ;
FUKASAWA, Y ;
KAZUMI, Y ;
TAKAHASHI, M ;
HIRANO, K ;
MORI, T .
JOURNAL OF CLINICAL MICROBIOLOGY, 1992, 30 (04) :878-881
[2]   Comparison of mycobacteria growth indicator tube with BACTEC 460 for detection and recovery of mycobacteria from clinical specimens [J].
Badak, FZ ;
Kiska, DL ;
Setterquist, S ;
Hartley, C ;
OConnell, MA ;
Hopfer, RL .
JOURNAL OF CLINICAL MICROBIOLOGY, 1996, 34 (09) :2236-2239
[3]  
*BBL, 1996, MGIT PROD DET MYC
[4]   Utility of PCR in diagnosing pulmonary tuberculosis [J].
Bennedsen, J ;
Thomsen, VO ;
Pfyffer, GE ;
Funke, G ;
Feldmann, K ;
Beneke, A ;
Jenkins, PA ;
Hegginbothom, M ;
Fahr, A ;
Hengstler, M ;
Cleator, G ;
Klapper, P ;
Wilkins, EGL .
JOURNAL OF CLINICAL MICROBIOLOGY, 1996, 34 (06) :1407-1411
[5]  
Costa R, 1995, Enferm Infecc Microbiol Clin, V13, P321
[6]  
David H, 1976, BACTERIOLOGY MYCOBAC
[7]  
DEAN AG, EPINFO 5 PROGRAMME I
[8]   RECOVERY OF MYCOBACTERIA FROM BLOOD IN MYCOBACTERIA GROWTH INDICATOR TUBE AND LOWENSTEIN-JENSEN SLANT AFTER LYSIS-CENTRIFUGATION [J].
HANNA, BA ;
WALTERS, SB ;
BONK, SJ ;
TICK, LJ .
JOURNAL OF CLINICAL MICROBIOLOGY, 1995, 33 (12) :3315-3316
[9]  
KUBICA GP, 1963, AM REV RESPIR DIS, V87, P775
[10]  
Nolte Frederick S., 1995, P400