Enhancing the sensitivity of capillary electrophoresis using a microcolumn solid phase extraction setup

被引:12
作者
Zhang, P
Xu, GW [1 ]
Xiong, JH
Zheng, YF
Shi, XZ
Yang, Q
Wei, FS
机构
[1] Chinese Acad Sci, Dalian Inst Chem Phys, Natl Chromatog R & A Ctr, Dalian 116011, Peoples R China
[2] China Natl Environm Monitoring Ctr, Beijing, Peoples R China
来源
JOURNAL OF SEPARATION SCIENCE | 2003年 / 26卷 / 17期
关键词
electrophoresis; micro-column solid-phase extraction; sensitivity; enrichment; sample; pretreatment;
D O I
10.1002/jssc.200301502
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this paper, a setup called micro-column solid phase extraction (MicroSPE) was developed to enhance the sensitivity of capillary electrophoresis. The setup consists of a manual pump, several insulin syringes, and a Teflon extraction cartridge. The cartridge was made of 2-4 mm irregular C-18 solid phase materials in a Teflon tube (375 mum ID) with glass fiber frits. Two pieces of capillary tubing were connected to both the ends of the cartridge. Using sulinclac-spiked urine as the test sample, the extraction and analytical conditions were investigated in detail. When 1 muL 70/30 methanol/water was applied as the elution solvent, satisfactory results could be obtained. The internal standard method was used to quantitatively determine the compound in urine. The detection limit for sulindac was 2.9 ng/mL and the enrichment factor reaches more than 260. The result illustrates that the MicroSPE setup has a significant concentrating effect and is suitable for preconcentrating and cleaning-up samples with complex matrices.
引用
收藏
页码:1527 / 1532
页数:6
相关论文
共 45 条
[1]   Sensitive and rapid method for the simultaneous quantification of five antidepressants with their respective metabolites in plasma using high-performance liquid chromatography with diode-array detection [J].
Aymard, G ;
Livi, P ;
Pham, YT ;
Diquet, B .
JOURNAL OF CHROMATOGRAPHY B, 1997, 700 (1-2) :183-189
[2]  
Bateman KP, 1998, J MASS SPECTROM, V33, P1109, DOI 10.1002/(SICI)1096-9888(199811)33:11<1109::AID-JMS728>3.0.CO
[3]  
2-1
[4]   APPLICATION OF CAPILLARY ZONE ELECTROPHORESIS WITH AN ISOTACHOPHORETIC INITIAL-STATE TO DETERMINE ANIONIC IMPURITIES ON AS-POLISHED SILICON-WAFER SURFACES [J].
BODEN, J ;
BACHMANN, K ;
KOTZ, L ;
FABRY, L ;
PAHLKE, S .
JOURNAL OF CHROMATOGRAPHY A, 1995, 696 (02) :321-332
[5]   Characterization of a solid-phase extraction device for discontinuous on-line preconcentration in capillary electrophoresis-based peptide mapping [J].
Bonneil, E ;
Waldron, KC .
JOURNAL OF CHROMATOGRAPHY B, 1999, 736 (1-2) :273-287
[6]   Determination of sulfonylurea degradation products in soil by liquid chromatography-ultraviolet detection followed by confirmatory liquid chromatography-tandem mass spectrometry [J].
Bossi, R ;
Vejrup, K ;
Jacobsen, CS .
JOURNAL OF CHROMATOGRAPHY A, 1999, 855 (02) :575-582
[7]  
Chien R. L., 1992, ANAL CHEM, V64, P489
[8]   SAMPLE STACKING OF AN EXTREMELY LARGE INJECTION VOLUME IN HIGH-PERFORMANCE CAPILLARY ELECTROPHORESIS [J].
CHIEN, RL ;
BURGI, DS .
ANALYTICAL CHEMISTRY, 1992, 64 (09) :1046-1050
[9]   Identification of proteins by capillary electrophoresis tandem mass spectrometry - Evaluation of an on-line solid-phase extraction device [J].
Figeys, D ;
Ducret, A ;
Aebersold, R .
JOURNAL OF CHROMATOGRAPHY A, 1997, 763 (1-2) :295-306
[10]  
Frazier RA, 1999, ELECTROPHORESIS, V20, P3156, DOI 10.1002/(SICI)1522-2683(19991001)20:15/16<3156::AID-ELPS3156>3.0.CO