A comparison between short ACTH and insulin stress tests for assessing hypothalamo-pituitary-adrenal function

被引:55
作者
Ammari, F [1 ]
Issa, BG [1 ]
Millward, E [1 ]
Scanlon, MF [1 ]
机构
[1] UNIV WALES COLL CARDIFF,COLL MED,DEPT DIABET ENDOCRINOL & METAB,CARDIFF CF4 4XN,S GLAM,WALES
关键词
D O I
10.1046/j.1365-2265.1996.712533.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVE Insulin-induced hypoglycaemia is the standard method for assessment of the hypothalamo-pituitary-adrenal (HPA) axis of patients with pituitary or hypothalamic disease. It has been claimed that a normal cortisol response to the 30-minute ACTH stimulation test (AST) obviates the need to perform the insulin stress test (IST) in these patients. The objective of our study was to compare both tests in a group of consecutive patients with pituitary disease. SUBJECTS AND METHODS Thirty patients with pituitary disease were evaluated by standard IST (0.1 U of soluble insulin/kg body weight, i.v.) after fasting from midnight and AST (250 mu g synacthen, i.v.). In the IST, a plasma glucose of <2.2 mmol/l was taken as the hypoglycaemic threshold and blood was collected at 0, 30, 60, 90 and 120 minutes. In the AST blood was collected at 0 and 30 minutes. Serum cortisol was measured by standard radioimmunoassay and glucose by the glucose oxidase method. Cortisol responses to the stimuli were compared at cut-off levels of 550, 500, 450 and 400 nmol/l. RESULTS At 550 nmol/l, out of 30 patients, 17 showed an abnormal IST of whom 9 had normal responses to AST (53%). At 500 nmol/l, 12 patients had an abnormal IST of whom 6 had normal AST (50%). At 450 nmol/l, of 9 patients with an abnormal IST, 5 had a normal AST (56%). At 400 nmol/l, 5 patients had an abnormal IST all of whom (100%) showed a normal AST. CONCLUSION There is a clear discrepancy between the results of the two tests at different cortisol cut-off levels. The ACTH stimulation test is not reliable for assessing the HPA axis in patients with pituitary disease and the insulin stress test remains the standard method.
引用
收藏
页码:473 / 476
页数:4
相关论文
共 14 条
[1]   DIAGNOSIS OF ADRENAL INSUFFICIENCY [J].
CLAYTON, RN .
BRITISH MEDICAL JOURNAL, 1989, 298 (6669) :271-272
[2]   NORMAL CORTISOL RESPONSE TO CORTICOTROPIN IN PATIENTS WITH SECONDARY ADRENAL FAILURE [J].
CUNNINGHAM, SK ;
MOORE, A ;
MCKENNA, TJ .
ARCHIVES OF INTERNAL MEDICINE, 1983, 143 (12) :2276-2279
[4]   THE OVERNIGHT SINGLE-DOSE METYRAPONE TEST IS A SIMPLE AND RELIABLE INDEX OF THE HYPOTHALAMIC-PITUITARY-ADRENAL AXIS [J].
FIAD, TM ;
KIRBY, JM ;
CUNNINGHAM, SK ;
MCKENNA, TJ .
CLINICAL ENDOCRINOLOGY, 1994, 40 (05) :603-609
[5]   PLASMA SUGAR FREE FATTY ACID CORTISOL AND GROWTH HORMONE RESPONSE TO INSULIN .I. IN CONTROL SUBJECTS [J].
GREENWOO.FC ;
LANDON, J ;
STAMP, TCB .
JOURNAL OF CLINICAL INVESTIGATION, 1966, 45 (04) :429-&
[6]  
Hagg E, 1981, Lakartidningen, V78, P4027
[7]  
Jacobs HS, 1969, Q J MED, V152, P475
[8]   SHORT ACTH TEST IN ASSESSING HYPOTHALAMIC-PITUITARY-ADRENOCORTICAL FUNCTION [J].
KEHLET, H ;
BLICHERTTOFT, M ;
LINDHOLM, J ;
RASMUSSEN, P .
BRITISH MEDICAL JOURNAL, 1976, 1 (6004) :249-251
[9]   2-HOUR ADRENOCORTICOTROPIC HORMONE TEST - ACCURACY IN EVALUATION OF HYPOTHALAMIC-PITUITARY-ADRENOCORTICAL AXIS [J].
LEISTI, S ;
PERHEENTUPA, J .
PEDIATRIC RESEARCH, 1978, 12 (04) :272-278
[10]   RELIABILITY OF 30-MINUTE ACTH TEST IN ASSESSING HYPOTHALAMIC-PITUITARY-ADRENAL FUNCTION [J].
LINDHOLM, J ;
KEHLET, H ;
BLICHERTTOFT, M ;
DINESEN, B ;
RIISHEDE, J .
JOURNAL OF CLINICAL ENDOCRINOLOGY & METABOLISM, 1978, 47 (02) :272-274