Transvenous biventricular defibrillation

被引:13
作者
Meisel, E
Butter, C
Philippon, F
Higgins, S
Strickberger, SA
Smith, J
Hahn, S
Michel, U
Schubert, B
Pfeiffer, D
机构
[1] Heart & Cardiovasc Ctr, Dresden, Germany
[2] Humboldt Univ, Charite, Berlin, Germany
[3] German Heart Inst, Berlin, Germany
[4] Dept Cardiol, Berlin, Germany
[5] Laval Hosp, Quebec City, PQ, Canada
[6] Scripps Mem Hosp, La Jolla, CA USA
[7] Univ Hosp, Ann Arbor, MI USA
[8] Barnes Jewish Hosp, St Louis, MO 63110 USA
[9] Guidant CRM, St Paul, MN USA
[10] Guidant CRM, Brussels, Belgium
[11] Univ Hosp, Leipzig, Germany
关键词
D O I
10.1016/S0002-9149(00)01295-9
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The recent success of biventricular pacing with transvenously implantable left ventricular leads suggests that left ventricular leads may be useful for other modes of therapy, Animal studies showed small leads inserted into a left ventricular vein dramatically reduced defibrillation strength requirements, This article describes a human investigation of the feasibility of biventricular defibrillation. Fifty-one patients undergoing implantable cardioverter defibrillator (ICD) implantation were enrolled. After insertion of a standard ICD lead, a prototype over-the-wire left ventricular defibrillation lead was inserted through the coronary sinus and into a vein on the left ventricle, Lead insertion was guided by retrograde venography, The left ventricular lead's location was randomized to the anterior or posterior vein, Randomized, paired defibrillation threshold (DFT) testing was performed to compare a standard ICD shock configuration (Control: right ventricle(-) --> superior vena cava(+) + CAN(+)) to 1 of 3 biventricular shock configurations. In the anterior vein, the left ventricular lead was tested with either a single biphasic shock from right ventricle + left ventricle- --> superior vena cava+ + CAN(+) or a dual biphasic shock, In the posterior vein, the left ventricular lead was tested with a dual biphasic shock. Dual shocks consisted of a 40% tilt biphasic shock from right ventricle- --> superior vena cava(+) + CAN(+) followed by another 40% tilt biphasic shock from left ventricle(-) --> superior vena cava(+) + CAN(+), delivered from a single 225 muF capacitance, Left ventricular lead positioning was successful in 41 of 46 patients (89%), Mean left ventricular lead insertion time was 17 +/- 17 minutes and 13 +/- 15 minutes for anterior and posterior locations, respectively. Mean DFTs were not statistically lower for the left ventricular shock configurations, but retrospective analysis showed a well-defined region of the posterolateral left ventricle where consistent DFT reduction was achieved with dual shocks (14.0 +/- 2.7 J vs 7.8 +/- 0.9 J; n = 5; p = 0.04). There were no adverse events requiring intervention doe to the use of the left ventricular lead. Biventricular defibrillation is feasible and safe under the conditions used in this study, Additional studies are needed to verify whether dual shocks with posterolateral left ventricular lead positions consistently reduce DFTs. (C) 2000 by Excerpta Medica, Inc.
引用
收藏
页码:76K / 85K
页数:10
相关论文
共 41 条
[1]  
Ansalone G, 1999, G Ital Cardiol, V29, P451
[2]  
Arruda M, 1998, PACING CLIN ELECTROP, V21, P853
[3]  
Auricchio A, 1999, AM J CARDIOL, V83, p130D
[4]  
AURICCHIO A, 1999, PACING CLIN ELECTROP, V22, P717
[5]   A SIMPLIFIED, SINGLE-LEAD UNIPOLAR TRANSVENOUS CARDIOVERSION-DEFIBRILLATION SYSTEM [J].
BARDY, GH ;
JOHNSON, G ;
POOLE, JE ;
DOLACK, GL ;
KUDENCHUK, PJ ;
KELSO, D ;
MITCHELL, R ;
MEHRA, R ;
HOFER, B .
CIRCULATION, 1993, 88 (02) :543-547
[6]   AN EFFECTIVE AND ADAPTABLE TRANSVENOUS DEFIBRILLATION SYSTEM USING THE CORONARY SINUS IN HUMANS [J].
BARDY, GH ;
ALLEN, MD ;
MEHRA, R ;
JOHNSON, G .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1990, 16 (04) :887-895
[7]   A method for permanent transvenous left ventricular pacing [J].
Blanc, JJ ;
Benditt, DG ;
Gilard, M ;
Etienne, Y ;
Mansourati, J ;
Lurie, KG .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1998, 21 (11) :2021-2024
[8]   TRANSVENOUS AND SUBCUTANEOUS ELECTRODE SYSTEM FOR AN IMPLANTABLE DEFIBRILLATOR, IMPROVED ON LARGE PIGS [J].
CANSELL, A ;
LECHAT, P ;
FONTAINE, G ;
GROSGOGEAT, Y ;
MEYERWAARDEN, K .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1988, 11 (11) :2008-2014
[9]   THE PROBABILITY OF DEFIBRILLATION SUCCESS AND THE INCIDENCE OF POSTSHOCK ARRHYTHMIA AS A FUNCTION OF SHOCK STRENGTH [J].
CATES, AW ;
WOLF, PD ;
HILLSLEY, RE ;
SOUZA, JJ ;
SMITH, WM ;
IDEKER, RE .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1994, 17 (07) :1208-1217
[10]   Multisite pacing for end-stage heart failure: Early experience [J].
Cazeau, S ;
Ritter, P ;
Lazarus, A ;
Gras, D ;
Backdach, H ;
Mundler, O ;
Mugica, J .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1996, 19 (11) :1748-1757