Characterization of a collinear double pulse laser-induced plasma at several ambient gas pressures by spectrally- and time-resolved imaging

被引:72
作者
Cristoforetti, G [1 ]
Legnaioli, S [1 ]
Palleschi, V [1 ]
Salvetti, A [1 ]
Tognoni, E [1 ]
机构
[1] CNR, Ist Proc Chimicofis, I-56124 Pisa, Italy
来源
APPLIED PHYSICS B-LASERS AND OPTICS | 2005年 / 80卷 / 4-5期
关键词
D O I
10.1007/s00340-005-1758-9
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
A collinear double pulse laser-induced plasma was characterised by means of a spectrally and time resolved imaging technique. The beams of two Q-switched Nd: YAG lasers were focused on a brass target in a vacuum chamber to form the plasma. The plume emission intensity and spatial distribution were recorded with temporal resolution using an intensified CCD. Using a set of interference filters, we collected images of the emission from the major target components as well as from oxygen. Both the laser inter-pulse separation ( in the range between 0 and 10 mu s) and the ambient air pressure value ( in the range between 10(5) and 10 Pa) were varied during the experiment. At atmospheric pressure, an enhancement of the line emission from the target elements was observed for delayed laser pulses compared to coincident pulses. However, this enhancement effect tends to fall at low pressure values, and a decrease of the signal is observed for pressures under about 10(4) Pa. Moreover, it was observed that the evaluation of the enhancement factor strongly depends on the detector field of view. The propagation of the emitting plume was also studied at several pressures and inter-pulse delays.
引用
收藏
页码:559 / 568
页数:10
相关论文
共 21 条
  • [1] [Anonymous], 1993, Similarity and Dimensional Methods in Mechanics
  • [2] Arnold N, 1999, APPL PHYS A-MATER, V69, pS87, DOI 10.1007/s003390051360
  • [3] A comparison of single and double pulse laser-induced breakdown spectroscopy of aluminum samples
    Colao, F
    Lazic, V
    Fantoni, R
    Pershin, S
    [J]. SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2002, 57 (07) : 1167 - 1179
  • [4] Three-dimensional analysis of laser induced plasmas in single and double pulse configuration
    Corsi, M
    Cristoforetti, G
    Giuffrida, M
    Hidalgo, M
    Legnaioli, S
    Palleschi, V
    Salvetti, A
    Tognoni, E
    Vallebona, C
    [J]. SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2004, 59 (05) : 723 - 735
  • [5] Influence of ambient gas pressure on laser-induced breakdown spectroscopy technique in the parallel double-pulse configuration
    Cristoforetti, G
    Legnaioli, S
    Palleschi, V
    Salvetti, A
    Tognoni, E
    [J]. SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2004, 59 (12) : 1907 - 1917
  • [6] ERSHOVPAVLOV E, 2003, P 2 EMSLIBS C I EL S, V12
  • [7] Laser-generated plasma plume expansion: Combined continuous-microscopic modeling
    Itina, TE
    Hermann, J
    Delaporte, P
    Sentis, M
    [J]. PHYSICAL REVIEW E, 2002, 66 (06): : 12
  • [8] ON THE INTERNAL STANDARDIZATION IN OPTICAL-EMISSION SPECTROMETRY OF MICROPLASMAS PRODUCED BY LASER ABLATION OF SOLID SAMPLES
    KO, JB
    SDORRA, W
    NIEMAX, K
    [J]. FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1989, 335 (07): : 648 - 651
  • [9] Resonance-enhanced laser-induced plasma spectroscopy: ambient gas effects
    Lui, SL
    Cheung, NH
    [J]. SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2003, 58 (09) : 1613 - 1623
  • [10] Space- and time-resolved dynamics of plasmas generated by laser double pulses interacting with metallic samples
    Noll, R
    Sattmann, R
    Sturm, V
    Winkelmarm, S
    [J]. JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2004, 19 (04) : 419 - 428