Compartment pressures after submuscular fixation of proximal tibia fractures

被引:8
作者
Cole, PA
Zlowodzki, M
Kregor, PJ
机构
[1] Univ Minnesota, Reg Hosp, Dept Orthoped Surg, St Paul, MN 55101 USA
[2] Vanderbilt Univ, Med Ctr, Dept Orthoped Surg, Div Orthoped Trauma, Nashville, TN USA
来源
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED | 2003年 / 34卷
关键词
compartment syndrome; compartment; tibial fractures; submuscular; LISS;
D O I
10.1016/S0020-1383(03)00257-2
中图分类号
R4 [临床医学];
学科分类号
1002 [临床医学]; 100602 [中西医结合临床];
摘要
Tibial fractures are known to be associated with elevated compartment pressures, which may potentially result in a compartment syndrome. The Tibial Less Invasive Stabilization System (LISS PLT) is an internal fixator device that is designed for fixation of proximal tibia fractures. The technique includes submuscular placement of the implant along the lateral border of the tibia. Such placement of the Tibia LISS into the anterior leg compartment could increase compartment pressures, and therefore increase the risk of compartment syndrome. The objective of this prospective study is to determine whether submuscular placement of a tibia LISS fixator increases compartment pressures and what is the incidence of compartment syndrome.
引用
收藏
页码:S43 / S46
页数:4
相关论文
共 9 条
[1]
COMPARTMENT SYNDROME IN OPEN TIBIAL FRACTURES [J].
BLICK, SS ;
BRUMBACK, RJ ;
POKA, A ;
BURGESS, AR ;
EBRAHEIM, NA .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1986, 68A (09) :1348-1353
[2]
COMPARTMENT PRESSURE IN ASSOCIATION WITH CLOSED TIBIAL FRACTURES - THE RELATIONSHIP BETWEEN TISSUE PRESSURE, COMPARTMENT, AND THE DISTANCE FROM THE SITE OF THE FRACTURE [J].
HECKMAN, MM ;
WHITESIDES, TE ;
GREWE, SR ;
ROOKS, MD .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1994, 76A (09) :1285-1292
[3]
HEPPENSTALL RB, 1988, CLIN ORTHOP RELAT R, V226, P138
[4]
MODEL COMPARTMENTAL SYNDROME IN MAN WITH PARTICULAR REFERENCE TO QUANTIFICATION OF NERVE FUNCTION [J].
MATSEN, FA ;
MAYO, KA ;
KRUGMIRE, RB ;
SHERIDAN, GW ;
KRAFT, GH .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1977, 59 (05) :648-653
[5]
MATSEN FA, 1978, SURG GYNECOL OBSTET, V147, P943
[6]
DIAGNOSIS AND MANAGEMENT OF COMPARTMENTAL SYNDROMES [J].
MATSEN, FA ;
WINQUIST, RA ;
KRUGMIRE, RB .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1980, 62 (02) :286-291
[7]
Compartment monitoring in tibial fractures [J].
McQueen, MM ;
CourtBrown, CM .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1996, 78B (01) :99-104
[8]
ACUTE COMPARTMENT SYNDROMES - DIAGNOSIS AND TREATMENT WITH AID OF WICK CATHETER [J].
MUBARAK, SJ ;
HARGENS, AR ;
AKESON, WH ;
OWEN, CA ;
GARETTO, LP .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1978, 60 (08) :1091-1095
[9]
Tornetta P 3rd, 1997, Instr Course Lect, V46, P303