Modification of DFIG's Active Power Control Loop for Speed Control Enhancement and Inertial Frequency Response

被引:36
作者
Ashouri-Zadeh, Alireza [1 ]
Toulabi, Mohammadreza [1 ]
Bahrami, Shahab [2 ]
Ranjbar, Ali Mohammad [1 ]
机构
[1] Sharif Univ Technol, Ctr Excellence Power Syst Management & Control, Tehran 1136511155, Iran
[2] Univ British Columbia, Dept Elect & Comp Engn, Vancouver, BC V6T 1Z4, Canada
关键词
Auxiliary frequency controller; doubly-fed induction generator (DFIG); fuzzy logic; inertial response; speed controller; DESIGN; SYSTEM;
D O I
10.1109/TSTE.2017.2710624
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This paper proposes a fuzzy-based speed controller for the doubly fed induction generator (DFIG)-based wind turbines with the rotor speed and wind speed inputs. The controller parameters are optimized using the particle swarm optimization algorithm. To accelerate tracking the maximum power point trajectory, the conventional controller is augmented with a feed-forward compensator, which uses the wind speed input and includes a high-pass filter. The proposed combined speed controller is robust against wind measurement errors and as the accuracy of anemometers increases the speed regulation tends toward the ideal controller. The cutoff frequency of the applied filter is determined considering a compromise between the sensitivity to measurement errors and speed of regulation process. We also design an auxiliary frequency controller to equip the DFIGs with an inertial frequency response. In the proposed controller, two important constraints are taken into account: the feasible rotor speed range during the injection period, and the minimum time to recover the DFIG's speed. The impacts of the proposed controllers are evaluated through extensive time-domain simulations on an IEEE 9-bus test system using the DIgSILENT/PowerFactory software. Results confirm the effectiveness of the proposed controllers in serious transients and load disturbances.
引用
收藏
页码:1772 / 1782
页数:11
相关论文
共 24 条
  • [1] Analytical evaluation of control strategies for participation of doubly fed induction generator-based wind farms in power system short-term frequency regulation
    Akbari, Mohammad
    Madani, Seyed M.
    [J]. IET RENEWABLE POWER GENERATION, 2014, 8 (03) : 324 - 333
  • [2] Anaya-Lara O., 2011, WIND ENERGY GENERATI
  • [3] [Anonymous], 2011, DYNAMIC MODELS WIND
  • [4] [Anonymous], 2012, Wind power in power systems
  • [5] Fuzzy Logic-Based Load-Frequency Control Concerning High Penetration of Wind Turbines
    Bevrani, Hassan
    Daneshmand, Pourya Ranjbar
    [J]. IEEE SYSTEMS JOURNAL, 2012, 6 (01): : 173 - 180
  • [6] A survey on analysis and design of model-based fuzzy control systems
    Feng, Gang
    [J]. IEEE TRANSACTIONS ON FUZZY SYSTEMS, 2006, 14 (05) : 676 - 697
  • [7] Investigating the Impacts of Wind Generation Participation in Interconnection Frequency Response
    Gevorgian, Vahan
    Zhang, Yingchen
    Ela, Erik
    [J]. IEEE TRANSACTIONS ON SUSTAINABLE ENERGY, 2015, 6 (03) : 1004 - 1012
  • [8] Doubly Fed Induction Generator (DFIG)-Based Wind Farm Control Framework for Primary Frequency and Inertial Response Application
    Ghosh, Sudipta
    Kamalasadan, Sukumar
    Senroy, Nilanjan
    Enslin, Johan
    [J]. IEEE TRANSACTIONS ON POWER SYSTEMS, 2016, 31 (03) : 1861 - 1871
  • [9] Dynamic Droop-Based Inertial Control of a Doubly-Fed Induction Generator
    Hwang, Min
    Muljadi, Eduard
    Park, Jung-Wook
    Sorensen, Poul
    Kang, Yong Cheol
    [J]. IEEE TRANSACTIONS ON SUSTAINABLE ENERGY, 2016, 7 (03) : 924 - 933
  • [10] Johnson G.L., 2006, WIND ENERGY SYSTEMS