Negative-sequence current injection for fast islanding detection of a distributed resource unit

被引:249
作者
Karimi, Houshang [1 ]
Yazdani, Amirnaser [2 ]
Iravani, Reza [1 ]
机构
[1] Univ Toronto, Ctr Appl Power Elect, Dept Elect & Comp Engn, Toronto, ON M5S 3G4, Canada
[2] Univ Western Ontario, Dept Elect & Comp Engn, London, ON N6A 5B9, Canada
关键词
distributed resource (DR); islanding detection; UL1741; test;
D O I
10.1109/TPEL.2007.911774
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper presents an active islanding detection method for a distributed resource (DR) unit which is coupled to a utility grid through a three-phase voltage-sourced converter (VSC). The method is based on injecting a negative-sequence current through the VSC controller and detecting and quantifying the corresponding negative-sequence voltage at the point of common coupling of the VSC by means of a unified three-phase signal processor (UTSP). UTSP is an enhanced phase-locked loop system which provides high degree of immunity to noise, and thus enable islanding detection based on injecting a small (< 3 %) negative-sequence current. The negative-sequence current is injected by a negative-sequence controller which is adopted as the complementary of the conventional VSC current controller. Based on simulation studies in the PSCAD/EMTDC environment, performance of the islanding detection method under UL1741 anti-islanding test is evaluated, and its sensitivity to noise, grid short-circuit ratio, grid voltage imbalance, and deviations in the UL1741 test parameters are presented. The studies show that based on negative-sequence current injection of about 2% to 3%, islanding can be detected within 60 ms even for the worst case scenario.
引用
收藏
页码:298 / 307
页数:10
相关论文
共 23 条
[1]  
[Anonymous], 2002, KING MUST DIESOME OB
[2]  
[Anonymous], 1741 UL STD
[3]  
*ANSI IEEE, 1989, 10011988 ANSI IEEE
[4]  
Bower W., 2002, SAND20023591 SAND NA
[5]   A phase tracking system for three phase utility interface inverters [J].
Chung, SK .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2000, 15 (03) :431-438
[6]  
Haykin S., 2002, ADAPTIVE FILTER THEO
[7]   Automatic phase-shift method for islanding detection of grid-connected photovoltaic inverters [J].
Hung, GK ;
Chang, CC ;
Chen, CL .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 2003, 18 (01) :169-173
[8]  
*IEEE, 2003, 1547 IEEE STD
[9]  
*IEEE, 2000, 929 IEEE STD
[10]   A method for synchronization of power electronic converters in polluted and variable-frequency environments [J].
Karimi-Ghartemani, M ;
Iravani, MR .
IEEE TRANSACTIONS ON POWER SYSTEMS, 2004, 19 (03) :1263-1270