Analysis of the liquid argon purity in the ICARUS T600 TPC

被引:57
作者
Amoruso, S
Antonello, M
Aprili, P
Arneodo, F
Badertscher, A
Balboussinov, B
Ceolin, MB
Battistoni, G
Bekman, B
Benetti, P
Bernardini, E
Bischofberger, M
di Tigliole, AB
Brunetti, R
Bruzzese, R
Bueno, A
Buzzanca, M
Calligarich, E
Campanelli, M
Carbonara, F
Carpanese, C
Cavalli, D
Cavanna, F
Cennini, P
Centro, S
Cesana, A
Chen, C
Chen, D
Chen, DB
Chen, Y
Cieslik, X
Cline, D
Cocco, AG
Dai, Z
De Vecchi, C
Dabrowska, A
Di Cicco, A
Dolfini, R
Ereditato, A
Felcini, M
Ferrari, A
Ferri, F
Fiorillo, G
Galli, S
Ge, Y
Gibin, D
Berzolari, AG
Gil-Botella, I
Graczyk, K
Grandi, L
机构
[1] Univ Granada, Dept Fis Teor & Cosmos, E-18071 Granada, Spain
[2] Univ Granada, CAFPE, E-18071 Granada, Spain
[3] Univ Naples Federico II, Naples, Italy
[4] Ist Nazl Fis Nucl, I-80125 Naples, Italy
[5] Univ Aquila, I-67100 Laquila, Italy
[6] Ist Nazl Fis Nucl, Laquila, Italy
[7] Ist Nazl Fis Nucl, Lab Nazl Gran Sasso, Assergi, Italy
[8] ETH Honggerberg, Inst Particle Phys, CH-8093 Zurich, Switzerland
[9] Univ Padua, Padua, Italy
[10] Ist Nazl Fis Nucl, Padua, Italy
[11] Univ Milan, Milan, Italy
[12] Ist Nazl Fis Nucl, I-20133 Milan, Italy
[13] Silesian Univ, Inst Phys, PL-40007 Katowice, Poland
[14] Univ Pavia, I-27100 Pavia, Italy
[15] Ist Nazl Fis Nucl, I-27100 Pavia, Italy
[16] CERN, Geneva, Switzerland
[17] Politecn Milan, CESNEF, I-20133 Milan, Italy
[18] Acad Sinica, Inst High Energy Phys, Beijing, Peoples R China
[19] H Niewodniczanski Inst Nucl Phys, PL-31342 Krakow, Poland
[20] Univ Calif Los Angeles, Dept Phys, Los Angeles, CA 90024 USA
[21] Univ Wroclaw, Inst Theoret Phys, PL-50138 Wroclaw, Poland
[22] Warsaw Univ, Inst Expt Phys, Warsaw, Poland
[23] A Soltan Inst Nucl Studies, Warsaw, Poland
[24] IFSI, Turin, Italy
[25] Univ Turin, Turin, Italy
[26] Ist Nazl Fis Nucl, Lab Nazl Frascati, I-00044 Frascati, Italy
[27] AGH Univ Sci & Technol, Krakow, Poland
[28] Ist Nazl Fis Nucl, Pisa, Italy
关键词
liquid argon; TPC; LAr purity; electron drift velocity;
D O I
10.1016/j.nima.2003.07.043
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The results reported in this paper are based on the analysis of the data recorded with the first half-module of the ICARUS T600 liquid argon Time Projection Chamber (LAr TPC), during a technical run that took place on surface in Pavia (Italy). We include results from the linearity, uniformity and calibration of the electronics, measurements on the electron drift velocity in LAr at different electric fields, as well as the LAr purity achievement of the detector. Two complementary techniques were used to measure the drift electron lifetime inside the active volume: the first, from the data of a purity monitor, gives a measurement localized in space; the second, based on the study of the signals produced by long minimum ionizing tracks crossing the detector, provides a LAr volume averaged value. Both methods yield consistent results over the whole data taking period and are compatible with an uniform LAr purity over the whole volume. The maximal drift electron lifetime value was recorded before the run stop and was about 1.8 ms. From an interpretation of the observed drift electron lifetime as a function of time, we conclude that the adopted technology would allow for drift distances exceeding 3 in. (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:68 / 79
页数:12
相关论文
共 8 条
[1]   Performance of the 10 m3 ICARUS liquid argon prototype [J].
Arneodo, F ;
Badertscher, A ;
Baiboussinov, B ;
Battistoni, G ;
Benetti, P ;
Bernardini, E ;
Bischofberger, M ;
di Tigliole, AB ;
Brunetti, R ;
Bueno, A ;
Calligarich, E ;
Campanelli, M ;
Carpanese, C ;
Cavalli, D ;
Cavanna, F ;
Cennini, P ;
Centro, S ;
Cesana, A ;
Chen, C ;
Chen, D ;
Chen, Y ;
Cline, D ;
De Vecchi, C ;
Di Credico, A ;
Dolfini, R ;
Ferrari, A ;
Ferri, F ;
Berzolari, AG ;
Gil-Botella, I ;
Grandi, L ;
Grillo, A ;
Haag, A ;
He, K ;
Huang, X ;
Kruse, A ;
Laffranchi, M ;
Li, Z ;
Lisowski, M ;
Lu, F ;
Ma, J ;
Matthey, C ;
Mauri, F ;
Mazza, D ;
Meng, G ;
Montanari, C ;
Muraro, S ;
Navas-Concha, S ;
Nicoletto, M ;
Nurzia, G ;
Otwinowski, S .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 498 (1-3) :292-311
[2]  
ARNEODO F, 1389 LNGSEXP
[3]   PERFORMANCE OF A 3-TON LIQUID ARGON TIME PROJECTION CHAMBER [J].
CENNINI, P ;
CITTOLIN, S ;
REVOL, JP ;
RUBBIA, C ;
TIAN, WH ;
PICCHI, P ;
CAVANNA, F ;
MORTARI, GP ;
VERDECCHIA, M ;
CLINE, D ;
MURATORI, G ;
OTWINOWSKI, S ;
WANG, H ;
ZHOU, M ;
BETTINI, A ;
CASAGRANDE, F ;
CASOLI, P ;
CENTRO, S ;
DAINESE, B ;
DEVECCHI, C ;
PEPATO, A ;
PIETROPAOLO, F ;
ROSSI, P ;
VENTURA, S ;
BENETTI, P ;
CALLIGARICH, E ;
DOLFINI, R ;
BERZOLARI, AG ;
MAURI, F ;
MAZZONE, L ;
MONTANARI, C ;
PIAZZOLI, A ;
RAPPOLDI, A ;
RASELLI, GL ;
SCANNICCHIO, D ;
PERIALE, L ;
SUZUKI, S .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 345 (02) :230-243
[4]   Detection of scintillation light in coincidence with ionizing tracks in a liquid argon time projection chamber [J].
Cennini, P ;
Revol, JP ;
Rubbia, C ;
Sergiampietri, F ;
Bueno, A ;
Campanelli, M ;
Goudsmit, P ;
Rubbia, A ;
Periale, L ;
Suzuki, S ;
Chen, C ;
Chen, Y ;
He, K ;
Huang, X ;
Li, Z ;
Lu, F ;
Ma, J ;
Xu, G ;
Xu, Z ;
Zhang, C ;
Zhang, Q ;
Zheng, S ;
Cavanna, F ;
Mazza, D ;
Piano Mortari, G ;
Petrera, S ;
Rossi, C ;
Mannocchi, G ;
Picchi, P ;
Arneodo, F ;
De Mitri, I ;
Palamara, O ;
Cavalli, D ;
Ferrari, A ;
Sala, P ;
di Tigliole, AB ;
Cesana, A ;
Terrani, M ;
Zavattari, C ;
Baibussinov, S ;
Bettini, A ;
Carpanese, C ;
Centro, S ;
Favaretto, D ;
Pascoli, D ;
Pepato, A ;
Pietropaolo, F ;
Ventura, S ;
Benetti, P ;
Calligarich, E .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 432 (2-3) :240-248
[5]  
*ICARUS COLL, 1994, LNGS9499I ICARUS COL
[6]  
*ICARUS COLL, UNPUB ICARUS T600 DE
[7]  
Rico J., 2002, THESIS ETH, P14906