Estimation of respiratory volumes from the photoplethysmographic signal.: Part I:: experimental results

被引:78
作者
Johansson, A [1 ]
Öberg, PÅ [1 ]
机构
[1] Linkoping Univ, Dept Biomed Engn, S-58185 Linkoping, Sweden
关键词
photoplethysmography; non-invasive measurements; respiratory volume; clinical monitoring;
D O I
10.1007/BF02513264
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
To evaluate the possibility of respiratory-volume measurement using photoplethysmography (PPG), PPG signals from 16 normal volunteers are collected, and the respiratory-induced intensity variations (RIIV) are digitally extracted. The RIIV signals are studied while respiratory volume is varied. Furthermore, respiratory rate, body posture and type of respiration are varied. A Fleisch pneumotachograph is used as the inspired volume reference. The RIIV and pneumotachograph signals are compared, and a statistical analysis is performed (linear regression and t-tests). The key idea is that the amplitude of the RIIV signal is related to the respiratory volume. The conclusion from the measurements is that there exists a relationship between the amplitude of the RIIV signal and the respiratory volume (R=0.842, s=0.428, p<0.005). Absolute measurements of the respiratory volume are not possible from the RIIV signal with the present set-up. The RIIV signal also seems to be affected by respiratory rate and type. More knowledge about respiratory parameters and improved sensor and filter design are required to make absolute measurements of volumes possible.
引用
收藏
页码:42 / 47
页数:6
相关论文
共 30 条
[1]   RESPIRATORY CONTROL OF HEART-RATE [J].
AHMED, AK ;
HARNESS, JB ;
MEARNS, AJ .
EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY AND OCCUPATIONAL PHYSIOLOGY, 1982, 50 (01) :95-104
[2]   VOLUMETRIC DYNAMICS OF RESPIRATION AS MEASURED BY ELECTRICAL IMPEDANCE PLETHYSMOGRAPHY [J].
ALLISON, RD ;
HOLMES, EL ;
NYBOER, J .
JOURNAL OF APPLIED PHYSIOLOGY, 1964, 19 (01) :166-&
[3]  
[Anonymous], 1865, CENTRALBLATT MED WIS
[4]   IMPEDANCE PNEUMOGRAPH AND MAGNETOMETER METHODS FOR MONITORING TIDAL VOLUME [J].
ASHUTOSH, K ;
GILBERT, R ;
AUCHINCLOSS, JH ;
ERLEBACHER, J ;
PEPPI, D .
JOURNAL OF APPLIED PHYSIOLOGY, 1974, 37 (06) :964-966
[5]  
Brecher GA, 1956, VENOUS RETURN
[6]  
CHALLONER AVJ, 1979, NONINVASIVE PHYSL ME, P125
[7]   AURA - A NEW RESPIRATORY MONITOR AND APNEA ALARM FOR SPONTANEOUSLY BREATHING PATIENTS [J].
CYNA, AM ;
KULKARNI, V ;
TUNSTALL, ME ;
HUTCHISON, JMS ;
MALLARD, JR .
BRITISH JOURNAL OF ANAESTHESIA, 1991, 67 (03) :341-345
[8]   COMPARISON OF CHANGES IN BLOOD VOLUME AND OPACITY IN DOG DIGITAL PAD AND TONGUE [J].
DAVIS, DL ;
BAKER, CH .
JOURNAL OF APPLIED PHYSIOLOGY, 1969, 27 (05) :613-&
[9]   PHOTO-ELECTRIC PLETHYSMOGRAPHY AS A MONITORING DEVICE IN ANESTHESIA - APPLICATION AND INTERPRETATION [J].
DORLAS, JC ;
NIJBOER, JA .
BRITISH JOURNAL OF ANAESTHESIA, 1985, 57 (05) :524-530
[10]  
ELDRUPJO.S, 1966, SURGERY, V59, P505