Comparison of nurse and computer charting of physiological variables in an intensive care unit

被引:14
作者
Cunningham, S
Deere, S
Elton, RA
McIntosh, N
机构
[1] Department of Child Life and Health, University of Edinburgh, Edinburgh, EH9 1UW
[2] Medical Statistics Unit, University of Edinburgh, Medical School, Edinburgh, EH8 9AG, Teviot Place
[3] Dept. of Child Life and Health, University of Edinburgh, Edinburgh, EH9 1UW
来源
INTERNATIONAL JOURNAL OF CLINICAL MONITORING AND COMPUTING | 1996年 / 13卷 / 04期
关键词
computers; intensive care; neonate; artifact; trend;
D O I
10.1023/A:1016967407632
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Objectives. To compare charting of physiological parameters manually by nurses and automatically by computer and so decide whether this task could accurately be performed by computer. Subjects/setting. 101 consecutive patients admitted for tertiary neonatal intensive care. Design. Direct comparison of 4X hours of data collected by both methods. Computer data stored each second and the hourly median compared with the single hourly value noted by the nurse. Methods. All patients were monitored by standard patient monitor and a computer. Four physiological parameters were compared between nurse and computer (both derived information from the standard patient monitor): heart rate, transcutaneous oxygen, mean blood pressure, central temperature. A random 51% of patients had the computer data displayed as trends at the cotside. Comparison of the hourly nurse observation and a computer hourly median value. Computer data was compared before and after the removal of artifact. In addition, the effects on nursing observations of either display or non display of the computer trend data was assessed. Results. Nurse and computer observations were statistically significantly different (p <0.001), though these were not clinically important. Nurses tended to note a higher figure than the computer median. The cotside display of computer data improved consistency between the nurse and computer observations. Artifact present in the data had little influence on the accuracy of the computer median value. Conclusions. Computer systems can accurately chart physiological data, providing a more flexible record with a minimal risk to data reliability from artifact.
引用
收藏
页码:235 / 241
页数:7
相关论文
共 23 条
[1]  
AUKBURG SJ, 1989, S COMP APPL MED CAR, P580
[2]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[3]  
BRADSHAW KE, 1988, S COMP APPL MED CAR, P763
[4]  
COLVIN JR, 1988, MED APPL MICROCOMPUT, P51
[5]  
COOK M, 1982, NURS TIMES, P1542
[6]   NEONATAL BRADYCARDIA FOLLOWING NASOPHARYNGEAL STIMULATION [J].
CORDERO, L ;
HON, EH .
JOURNAL OF PEDIATRICS, 1971, 78 (03) :441-+
[7]  
CORRIE J, 1993, BRIT J INT CARE, V3, P225
[8]   THE PRACTICAL MANAGEMENT OF ARTIFACT IN COMPUTERIZED PHYSIOLOGICAL DATA [J].
CUNNINGHAM, S ;
SYMON, AG ;
MCINTOSH, N .
INTERNATIONAL JOURNAL OF CLINICAL MONITORING AND COMPUTING, 1994, 11 (04) :211-216
[9]   NEONATAL PHYSIOLOGICAL TREND MONITORING BY COMPUTER [J].
CUNNINGHAM, S ;
DEERE, S ;
ELTON, RA ;
MCINTOSH, N .
INTERNATIONAL JOURNAL OF CLINICAL MONITORING AND COMPUTING, 1992, 9 (04) :221-227
[10]  
CUNNINGHAM S, 1991, INT CONGR SER, V967, P191