Renal effects of CO2 and iodinated contrast media in patients undergoing renovascular intervention:: A prospective, randomized study

被引:24
作者
Liss, P [1 ]
Eklöf, H
Hellberg, O
Hägg, A
Boström-Ardin, A
Löfberg, AM
Olsson, U
Örndahl, P
Nilsson, H
Hansell, P
Eriksson, LG
Bergqvist, D
Nyman, R
机构
[1] Uppsala Univ, Dept Radiol, Uppsala, Sweden
[2] Uppsala Univ, Dept Internal Med, Uppsala, Sweden
[3] Uppsala Univ, Dept Surg, Uppsala, Sweden
[4] Uppsala Univ, Dept Cell Biol, Uppsala, Sweden
[5] Swedish Univ Agr Sci, Dept Biometry & Engn, Uppsala, Sweden
关键词
D O I
10.1097/01.RVI.0000144807.81633.79
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: CO2 gas has been proposed for use instead of iodinated contrast media in angiographic examinations in patients at risk of developing renal failure from contrast media. The influence of intraarterial injection of CO2 with small added amounts of ioxaglate (200 mgI/mL) or ioxaglate alone on renal function in patients with suspected renal artery stenosis was studied in a prospective, randomized study. MATERIALS AND METHODS: One hundred twenty-three patients underwent renovascular intervention (n = 83) and/or renal angiography (n = 40) for suspected renal artery stenosis. Patients with a serum creatinine concentration less than 200 mu mol/L (n = 82) were randomized prospectively to receive CO2 with small added amounts of ioxaglate (n = 37) or only ioxaglate (n = 45). Patients with serum creatinine levels greater than 200 mu mol/L (n = 41) were not randomized and initially received CO, Serum creatinine concentrations were measured within 1 day before and 1 day, 2 days, and 2-3 weeks after the procedure. RESULTS: The amount of injected CO2 did not relate to an increase in serum creatinine level. In the randomized groups, and also when the whole patient sample was considered, the amount of injected iodine was significantly correlated (P = .011) with an increase in serum creatinine level and a decrease in estimated creatinine clearance after 2 days. Among the randomized patients, one in the CO2 group and three in the ioxaglate group had a more than 25% increase in serum creatinine level within the first 2 days after the intervention. CONCLUSION: The risk of impairment of renal function is lower after injection of CO2 with small amounts of added ioxaglate compared with injection of a larger amount of ioxaglate alone. The larger the amount of administered iodinated contrast medium, the greater the risk of development of renal failure.
引用
收藏
页码:57 / 65
页数:9
相关论文
共 47 条
[1]  
AREND LJ, 1987, J LAB CLIN MED, V110, P406
[2]   Nephrotoxic effects in high-risk patients undergoing angiography. [J].
Aspelin, P ;
Aubry, P ;
Fransson, S ;
Strasser, R ;
Willenbrock, R ;
Berg, KJ .
NEW ENGLAND JOURNAL OF MEDICINE, 2003, 348 (06) :491-499
[3]   A ROLE FOR CALCIUM IN RADIOCONTRAST-INDUCED REDUCTIONS IN RENAL HEMODYNAMICS [J].
BAKRIS, GL ;
BURNETT, JC .
KIDNEY INTERNATIONAL, 1985, 27 (02) :465-468
[4]   Renal angiography using carbon dioxide [J].
Beese, RC ;
Bees, NR ;
Belli, AM .
BRITISH JOURNAL OF RADIOLOGY, 2000, 73 (865) :3-6
[5]  
BRENNER M, 1988, KIDNEY, P319
[6]   A CLOSER LOOK AT RADIOCONTRAST-INDUCED NEPHROPATHY [J].
BREZIS, M ;
EPSTEIN, FH .
NEW ENGLAND JOURNAL OF MEDICINE, 1989, 320 (03) :179-181
[7]   MECHANISMS OF DISEASE - HYPOXIA OF THE RENAL MEDULLA - ITS IMPLICATIONS FOR DISEASE [J].
BREZIS, M ;
ROSEN, S .
NEW ENGLAND JOURNAL OF MEDICINE, 1995, 332 (10) :647-655
[8]  
BREZIS M, 1984, AM J PATHOL, V116, P327
[9]   RENAL TOLERANCE OF GADOLINIUM-DOTA AND GADOLINIUM-DTPA IN RATS [J].
BRILLET, G ;
DUBOIS, M ;
BEAUFILS, H ;
BOURBOUZE, R ;
DERAY, G .
INVESTIGATIVE RADIOLOGY, 1994, 29 (03) :352-354
[10]   CO2 digital subtraction angiography for renal artery angioplasty in high-risk patients [J].
Caridi, JG ;
Stavropoulos, SW ;
Hawkins, IF .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1999, 173 (06) :1551-1556