Static and dynamic operating characteristics of a pericardial balloon

被引:14
作者
Hamilton, DR
Devries, G
Tyberg, JV
机构
[1] Univ Calgary, Hlth Sci Ctr, Dept Med, Calgary, AB T2N 4N1, Canada
[2] Univ Calgary, Hlth Sci Ctr, Dept Physiol Biophys, Calgary, AB T2N 4N1, Canada
关键词
pericardium; pericardial pressure; transducer; frequency response; epicardial stress;
D O I
10.1152/jappl.2001.90.4.1481
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
Previously, we developed a balloon transducer to measure the constraint of the pericardium (i.e., pericardial pressure) on the surface of the heart. It was validated physiologically in that it was shown to measure a pressure equal to the difference between the left ventricular end-diastolic pressure measured before and after pericardiectomy at the same left ventricular volume. To define its static operating characteristics, we loaded the balloon nonuniformly with weights that covered fractions of the balloon surface and found that the balloon accurately recorded the average stress if the stress was applied over at least 23% of its surface. To test its performance when curved, we placed it in large and small cylinders (minimum diameter 31 mm) and found that the balloon accurately recorded the stress. To define its dynamic operating characteristics, we applied sinusoidal stresses and found that its frequency response was limited only by that of the connecting catheter. When better dynamic response is required, we introduce a micromanometer-tipped catheter to obtain a unity-gain frequency response that is flat to 200 Hz.
引用
收藏
页码:1481 / 1488
页数:8
相关论文
共 31 条
[1]   MECHANICS OF PLEURAL SPACE [J].
AGOSTONI, E .
PHYSIOLOGICAL REVIEWS, 1972, 52 (01) :57-&
[2]   EXTERNAL-PRESSURE OF UNDISTURBED LEFT-VENTRICLE [J].
APPLEGATE, RJ ;
SANTAMORE, WP ;
KLOPFENSTEIN, HS ;
LITTLE, WC .
AMERICAN JOURNAL OF PHYSIOLOGY, 1990, 258 (04) :H1079-H1086
[3]   INFLUENCE OF THE PERICARDIUM ON RIGHT AND LEFT-VENTRICULAR FILLING IN THE DOG [J].
ASSANELLI, D ;
LEW, WYW ;
SHABETAI, R ;
LEWINTER, MM .
JOURNAL OF APPLIED PHYSIOLOGY, 1987, 63 (03) :1025-1032
[4]   PLEURAL AND ESOPHAGEAL PRESSURES IN UPRIGHT BODY POSITION [J].
BANCHERO, N ;
SCHWARTZ, PE ;
TSAKIRIS, AG ;
WOOD, EH .
JOURNAL OF APPLIED PHYSIOLOGY, 1967, 23 (02) :228-&
[5]  
BARNARD HL, 1898, J PHYSIOL-LONDON, V22, P43
[6]   VENTRICULAR INTERACTION DURING EXPERIMENTAL ACUTE PULMONARY-EMBOLISM [J].
BELENKIE, I ;
DANI, R ;
SMITH, ER ;
TYBERG, JV .
CIRCULATION, 1988, 78 (03) :761-768
[7]   INTRAOPERATIVE MEASUREMENT OF PERICARDIAL CONSTRAINT - ROLE IN VENTRICULAR DIASTOLIC MECHANICS [J].
BOLTWOOD, CM ;
SKULSKY, A ;
DRINKWATER, DC ;
LANG, S ;
MULDER, DG ;
SHAH, PM .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1986, 8 (06) :1289-1297
[8]  
BOYD I. A., 1964, SCOT MED J, V9, P345
[9]   DETERMINANTS OF INTRAPERICARDIAL PRESSURE IN DOGS [J].
FREEMAN, GL ;
LEWINTER, MM .
JOURNAL OF APPLIED PHYSIOLOGY, 1986, 60 (03) :758-764
[10]   RIGHT ATRIAL AND RIGHT-VENTRICULAR TRANSMURAL PRESSURES IN DOGS AND HUMANS - EFFECTS OF THE PERICARDIUM [J].
HAMILTON, DR ;
DANI, RS ;
SEMLACHER, RA ;
SMITH, ER ;
KIESER, TM ;
TYBERG, JV .
CIRCULATION, 1994, 90 (05) :2492-2500