Determination of heavy metals by inductively coupled plasma mass spectrometry after on-line separation and preconcentration

被引:128
作者
Dressler, VL [1 ]
Pozebon, D [1 ]
Curtius, AJ [1 ]
机构
[1] Univ Fed Santa Catarina, Dept Quim, BR-88040900 Florianopolis, SC, Brazil
关键词
inductively coupled plasma mass spectrometry; flow injection analysis; O; O-diethyl dithiophosphoric acid; pre-concentration; certified reference material;
D O I
10.1016/S0584-8547(98)00180-3
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
A method for the determination of Cu, As, Se, Cd, In, Hg, Tl, Pb and Bi in waters and in biological materials by inductively coupled plasma mass spectrometry, after an on-line separation, is described. The matrix separation and analyte preconcentration is accomplished by retention of the analytes complexed with the ammonium salt of O,O-diethyl dithiophosphoric acid in a HNO3 solution on C-18 immobilized on silica in a minicolumn. Methanol, as eluent, is introduced in the conventional pneumatic nebulizer of the instrument. In order to use the best compromise conditions, concerning the ligand and acid concentrations, the analytes were determined in two separate groups. The enrichment factors were in the range from 5 to 61, depending on the analyte. The limits of detection varied from 0.43 ng L-1 for Bi to 33 ng L-1 for Cu. The sample consumption is only 2.3 mL for each group and the sampling frequency is 21 h(-1). The accuracy was tested by analysing five certified reference materials: water, riverine water, urine, bovine muscle and bovine liver. The agreement between obtained and certified concentrations was very good, except for As. The relatively small volume of methanol, used as eluent, minimizes the problems produced by the introduction of organic solvent into the plasma. (C) 1998 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:1527 / 1539
页数:13
相关论文
共 54 条
[1]   SIGNAL ENHANCEMENT OF ELEMENTS DUE TO THE PRESENCE OF CARBON-CONTAINING COMPOUNDS IN INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY [J].
ALLAIN, P ;
JAUNAULT, L ;
MAURAS, Y ;
MERMET, JM ;
DELAPORTE, T .
ANALYTICAL CHEMISTRY, 1991, 63 (14) :1497-1498
[2]   DETERMINATION OF SILVER IN WATERS AND SOIL BY ELECTROTHERMAL ATOMIC-ABSORPTION SPECTROMETRY AFTER COMPLEXATION AND SORPTION ON CARBON [J].
AVILA, AK ;
CURTIUS, AJ .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1994, 9 (04) :543-546
[3]   DETERMINATION OF TRACE-METALS IN REFERENCE WATER STANDARDS BY INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY WITH ONLINE PRECONCENTRATION [J].
BEAUCHEMIN, D ;
BERMAN, SS .
ANALYTICAL CHEMISTRY, 1989, 61 (17) :1857-1862
[4]  
BERES S, 1994, SPECTROSCOPY, V9, P20
[5]   DETERMINATION OF TRACE-METALS IN SEA-WATER AND THE ONLINE REMOVAL OF MATRIX INTERFERENCES BY FLOW-INJECTION WITH INDUCTIVELY-COUPLED PLASMA-MASS SPECTROMETRIC DETECTION [J].
BLOXHAM, MJ ;
HILL, SJ ;
WORSFOLD, PJ .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1994, 9 (09) :935-938
[6]  
BODE H, 1962, FRESEN Z ANAL CHEM, V185, P99
[7]  
BODE H, 1962, Z ANAL CHEM, V185, P179
[8]   Direct determination of Se and As in solid certified reference materials using electrothermal vaporization inductively coupled plasma mass spectrometry [J].
Boonen, S ;
Vanhaecke, F ;
Moens, L ;
Dams, R .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1996, 51 (02) :271-278
[9]  
BROADHEAD M, 1991, ATOM SPECTROSC, V12, P45
[10]   EVALUATION OF 3 LOW-VOLUME INTERFACES FOR ORGANIC-SOLVENT INTRODUCTION TO THE INDUCTIVELY COUPLED PLASMA - APPLICATIONS TO FLOW-INJECTION [J].
BROTHERTON, TJ ;
PFANNERSTILL, PE ;
CREED, JT ;
HEITKEMPER, DT ;
CARUSO, JA ;
PRATSINIS, SE .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1989, 4 (04) :341-345