Comparison of carotid vessel wall area measurements using three different contrast-weighted black blood MR imaging techniques

被引:48
作者
Zhang, SX [1 ]
Hatsukami, TS
Polissar, NL
Han, C
Yuan, C
机构
[1] Chinese Acad Med Sci, Dept Radiol, Cardiovasc Inst, Beijing 100037, Peoples R China
[2] Chinese Acad Med Sci, Fu Wai Hosp, Beijing 100037, Peoples R China
[3] Beijing Union Med Coll, Beijing 100037, Peoples R China
[4] Univ Washington, Dept Radiol, Seattle, WA 98195 USA
[5] Univ Washington, Div Vasc Surg, Seattle, WA 98195 USA
[6] Mt Whisper Light Stat Consulting, Natori, Miyagi 98112, Japan
关键词
carotid artery; atherosclerosis; area measurement; MR imaging;
D O I
10.1016/S0730-725X(01)00408-8
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Measuring carotid artery plaque burden from MRI is a reliable method for monitoring regression and progression of atherosclerosis. However, to measure all available images would be very time consuming, and in practice the image quality (IQ) of these images may be inconsistent, which can directly impact the quality of measurement. It is hypothesized that if IQ is comparable among different contrast weighted images, then carotid artery area measurements obtained from different contrast images of the same location will produce identical results. To test this, T1, proton density and T2 weighted images were acquired from ten patients (51 +/-7 years old). Carotid lumen and vessel wall area was measured using a custom designed software program. The results showed strong agreement evidenced with only small differences on both lumen (mean: 40.5 mm(2)) and wall (mean: 52.6 mm(2)) area measurement among different weighted images. The maximum absolute mean differences are less than 2.7 mm(2) and 4.4 mm(2) and 90(th) percentile of the absolute differences are 5.6 mm(2) and 8.2 mm(2) respectively. In conclusion. different contrast weighted images with high and comparable IQ will yield similar results in lumen and vessel wall area measurement. At each matched location, it is recommended that the image with the highest IQ be used for area measurement. (C) 2001 Elsevier Science Inc. All rights reserved.
引用
收藏
页码:795 / 802
页数:8
相关论文
共 30 条
[1]   Juxtalumenal location of plaque necrosis and neoformation in symptomatic carotid stenosis [J].
Bassiouny, HS ;
Sakaguchi, Y ;
Mikucki, SA ;
McKinsey, JF ;
Piano, G ;
Gewertz, BL ;
Glagov, S .
JOURNAL OF VASCULAR SURGERY, 1997, 26 (04) :585-594
[2]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[3]  
DAVIES MJ, 1985, BRIT HEART J, V53, P363
[4]  
Desai M M, 1999, MMWR CDC Surveill Summ, V48, P7
[5]   Noninvasive in vivo high-resolution magnetic resonance imaging of atherosclerotic lesions in genetically engineered mice [J].
Fayad, ZA ;
Fallon, JT ;
Shinnar, M ;
Wehrli, S ;
Dansky, HM ;
Poon, M ;
Badimon, JJ ;
Charlton, SA ;
Fisher, EA ;
Breslow, JL ;
Fuster, V .
CIRCULATION, 1998, 98 (15) :1541-1547
[6]   In vivo magnetic resonance evaluation of atherosclerotic plaques in the human thoracic aorta - A comparison with transesophageal echocardiography [J].
Fayad, ZA ;
Nahar, T ;
Fallon, JT ;
Goldman, M ;
Aguinaldo, JG ;
Badimon, JJ ;
Shinnar, M ;
Chesebro, JH ;
Fuster, V .
CIRCULATION, 2000, 101 (21) :2503-2509
[7]  
Fayad ZA, 2000, CIRCULATION, V102, P506
[8]  
Gronholdt MLM, 1998, EUR HEART J, V19, pC24
[9]   Visualization of fibrous cap thickness and rupture in human atherosclerotic carotid plaque in vivo with high-resolution magnetic resonance imaging [J].
Hatsukami, TS ;
Ross, R ;
Polissar, NL ;
Yuan, C .
CIRCULATION, 2000, 102 (09) :959-964
[10]  
HAYES CE, 1996, JMRI-J MAGN RESON IM, V1, P109