Bone response to radio frequency sputtered calcium phosphate implants and titanium implants in vivo

被引:46
作者
Ong, JL
Bessho, K
Cavin, R
Carnes, DL
机构
[1] Univ Texas, Hlth Sci Ctr, Dept Restorat Dent, Div Biomat, San Antonio, TX 78284 USA
[2] Kyoto Univ, Grad Sch med, Dept Oral & Maxillofacial Surg, Sakyo Ku, Kyoto 6068507, Japan
[3] Univ Texas, Hlth Sci Ctr, Dept Periodont, San Antonio, TX 78229 USA
来源
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH | 2002年 / 59卷 / 01期
关键词
calcium phosphate; sputter coatings; heat treatment; histology; ultimate interfacial strength;
D O I
10.1002/jbm.1232
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The objective of this study was to evaluate the effect of radio frequency sputtered calcium phosphate (CaP) coatings of titanium (Ti) implants on the bond strength at the bone-implant interface and percent bone contact length. Cylindrical coated or noncoated implants (4.0-mm diameter by 8-mm long) were implanted for 3 and 12 weeks. At 3 weeks after implant placement, the ultimate interfacial strengths for as-deposited CaP-coated and heat-treated Cap-coated implants were 2.29 +/- 0.14 MPa and 1.28 +/- 0.04 MPa, respectively. These ultimate interfacial strength values at 3 weeks were statistically greater than the mean ultimate interfacial strength for control Ti implants (0.67 +/- 0.13 MPa). At 12 weeks after implant placement, no statistical differences in the mean ultimate interfacial strengths were observed between the as-deposited CaP-coated, heat-treated CaP-coated, and control Ti implants. Histomorphometric evaluation indicated greater percent bone contact lengths for the as-deposited CaP-coated implants compared with the heat-treated CaP-coated and control Ti implants 3 and 12 weeks after implant placement. (C) 2001 John Wiley & Sons, Inc.
引用
收藏
页码:184 / 190
页数:7
相关论文
共 26 条
[1]  
DEBRUIJN JD, 1993, CELL MATER, V3, P407
[2]  
DHERT WJA, 1991, CERAMICS SUBSTITUTIV, P385
[3]   CHARACTERIZATION OF THE INTERFACE IN THE PLASMA-SPRAYED HA COATING/TI-6AL-4V IMPLANT SYSTEM [J].
FILIAGGI, MJ ;
COOMBS, NA ;
PILLIAR, RM .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1991, 25 (10) :1211-1229
[4]   DIFFERENCE OF BOND BONDING BEHAVIOR AMONG SURFACE-ACTIVE GLASSES AND SINTERED APATITE [J].
FUJIU, T ;
OGINO, M .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1984, 18 (07) :845-859
[5]  
GABBI C, 1992, T 4 WORLD BIOM C, P5
[6]  
Gotfredsen K, 1992, Clin Oral Implants Res, V3, P77, DOI 10.1034/j.1600-0501.1992.030205.x
[7]  
Hench L L, 1988, Ann N Y Acad Sci, V523, P54, DOI 10.1111/j.1749-6632.1988.tb38500.x
[8]  
Johansson C, 1987, Int J Oral Maxillofac Implants, V2, P69
[9]  
KELLER JC, 1995, J DENT RES, V74, P22
[10]  