The effect of luting media on the fracture resistance of a flame sprayed all-ceramic crown

被引:24
作者
Casson, AM [1 ]
Jones, JCG [1 ]
Youngson, CC [1 ]
Wood, DJ [1 ]
机构
[1] Leeds Dent Inst, Div Restorat Dent, Leeds LS2 9LU, W Yorkshire, England
关键词
fracture resistance; luting agent; all-ceramic crown; failure;
D O I
10.1016/S0300-5712(01)00040-9
中图分类号
R78 [口腔科学];
学科分类号
1003 [口腔医学];
摘要
Objectives: This in vitro study investigated the effect of selected luting media on the fracture resistance of a flame-sprayed all-ceramic crown. Methods: Three groups of 10 human upper premolar teeth were prepared for crowning using a standardised technique. Flame sprayed crowns were fabricated and cemented onto the preparations using zinc phosphate (ZPC), glass polyalkenoate (GPC) or composite luting cement (CLC). During crown seating, a pressure perfusion system simulated pulpal fluid outflow equivalent to 300 mm. of H2O. Compressive fracture resistance was determined for each group using a Universal Testing Machine with a crosshead speed of 1 mna min A group of unrestored teeth acted as a control. Results: The fracture resistance of the groups ranked as follows: ZPC > CLC much greater than GPC = unrestored teeth. The difference between the fracture resistance of ZPC and CLC groups and the control group was statistically significant. The mode of fracture between the luted crowns and natural crowns was markedly different. Conclusions: When tested in compression, a new, flame-sprayed all-ceramic crown, when luted in place using ZPC, GPC or CLC, could produce strengths comparable to or greater than natural unrestored teeth. The luting agent used significantly affected the recorded fracture loads. (C) 2001 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:539 / 544
页数:6
相关论文
共 32 条
[1]
Bebermeyer R D, 1994, Quintessence Int, V25, P209
[2]
BRECKER SC, 1956, J PROS DENT, V6, P801
[3]
*BRIT SOC REST DEN, 1999, EUR J PROSTHODONT RE, V7, P3
[4]
COMPRESSIVE STRENGTHS OF A NEW FOIL AND PORCELAIN-FUSED-TO-METAL CROWNS [J].
BRUKL, CE ;
OCAMPO, RR .
JOURNAL OF PROSTHETIC DENTISTRY, 1987, 57 (04) :404-410
[5]
Burke F J, 1995, Quintessence Int, V26, P293
[6]
Burke F J, 1994, Quintessence Int, V25, P335
[7]
Burke FJT, 1998, QUINTESSENCE INT, V29, P21
[8]
TOOTH FRACTURE INVIVO AND INVITRO [J].
BURKE, FJT .
JOURNAL OF DENTISTRY, 1992, 20 (03) :131-139
[9]
CERAMIC VS PORCELAIN-FUSED-TO-METAL CROWNS - GIVE YOUR PATIENTS A CHOICE [J].
CHRISTENSEN, GJ .
JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 1994, 125 (03) :311-&
[10]
Dwan A, 1996, J DENT RES, V75, P2136