Comparison of three-point bending test and peripheral quantitative computed tomography analysis in the evaluation of the strength of mouse femur and tibia

被引:201
作者
Jämsä, T
Jalovaara, P
Peng, Z
Väänänen, HK
Tuukkanen, J
机构
[1] Univ Oulu, Fac Med, Tech Serv Unit, FIN-90220 Oulu, Finland
[2] Univ Oulu, Dept Surg, Biomed Engn Program, FIN-90220 Oulu, Finland
[3] Univ Oulu, Dept Anat, FIN-90220 Oulu, Finland
[4] Univ Oulu, Bioctr Oulu, FIN-90220 Oulu, Finland
[5] Univ Turku, Inst Biomed, Dept Anat, FIN-20520 Turku, Finland
关键词
three-point bending; bending strength; cortical density; BMD; bone geometry; murine model;
D O I
10.1016/S8756-3282(98)00076-3
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
We compared the mechanical and densitometric testing methods in evaluating the mechanical strength of mouse cortical hones, The femora and tibiae of 10 male mice (weight 32.8 +/- 4.0 g) mere utilized, Volumetric cortical bone mineral density (VCtBMD), cross-sectional cortical area at midshaft (CSA), cross-sectional moment of inertia (CSMI), and strength strain index (SSI) mere measured by peripheral quantitative computed tomography (pQCT), The precision of pQCT expressed as a coefficient of variation (CV) was 1.1%, 2.7%, and 6.4% for vCtBMD, CSA, and CSMI, respectively. The mechanical properties were measured by a three-point bending test. The method error measured from paired bones mas 7.3%-10.1% for breaking bending force, 15.0%-15.2% for stiffness, 2.0%-2.4% for vCtBMD, 5.2%-6.4% for CSA, 13.5%-17.6% for CSMI, and 8.9%-18.1% for SSI, CSMI and CSA mere found to be the best explanatory variables for the breaking force of femur and tibial respectively, while CSI-I and CSMI were the best predictors for the elastic modulus of femur and tibia, respectively, CSA had a higher correlation with mechanical parameters than VCtBMD. On the basis of this study, the mechanical tests and the pQCT measurements are relevant in biomechanical studies on mouse bones and justify the use of the murine model, High-resolution pQCT gives better precision than the three-point bending test in studies of mouse bones. (Bone 23:155-161; 1998) (C) 1998 by Elsevier Science Int. All rights reserved.
引用
收藏
页码:155 / 161
页数:7
相关论文
共 53 条
[1]   Transgenic mice expressing soluble tumor necrosis factor-receptor are protected against bone loss caused by estrogen deficiency [J].
Ammann, P ;
Rizzoli, R ;
Bonjour, JP ;
Bourrin, S ;
Meyer, JM ;
Vassalli, P ;
Garcia, I .
JOURNAL OF CLINICAL INVESTIGATION, 1997, 99 (07) :1699-1703
[2]   RECOVERY FROM DISUSE OSTEOPENIA COINCIDENT TO RESTORATION OF MUSCLE STRENGTH IN MDX MICE [J].
ANDERSON, JE ;
LENTZ, DL ;
JOHNSON, RB .
BONE, 1993, 14 (04) :625-634
[3]  
Augat P, 1996, J BONE MINER RES, V11, P1356
[4]  
BEAMER W, 1997, J BONE MINER RES, V12, pS174
[5]   Genetic variability in adult bone density among inbred strains of mice [J].
Beamer, WG ;
Donahue, LR ;
Rosen, CJ ;
Baylink, DJ .
BONE, 1996, 18 (05) :397-403
[6]  
BEAMER WG, 1996, J BONE MINER RES, V11, pS406
[7]   TRANSGENIC MOUSE MODEL OF THE MILD DOMINANT FORM OF OSTEOGENESIS IMPERFECTA [J].
BONADIO, J ;
SAUNDERS, TL ;
TSAI, E ;
GOLDSTEIN, SA ;
MORRISWIMAN, J ;
BRINKLEY, L ;
DOLAN, DF ;
ALTSCHULER, RA ;
HAWKINS, JE ;
BATEMAN, JF ;
MASCARA, T ;
JAENISCH, R .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1990, 87 (18) :7145-7149
[8]  
Breen SA, 1996, CALCIFIED TISSUE INT, V58, P449, DOI 10.1007/BF02509446
[9]  
BREEN SA, 1996, J BONE MINER RES, V11, pS471
[10]   EFFECTS OF REHYDRATION STATE ON THE FLEXURAL PROPERTIES OF WHOLE MOUSE LONG BONES [J].
BROZ, JJ ;
SIMSKE, SJ ;
GREENBERG, AR ;
LUTTGES, MW .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1993, 115 (04) :447-449