Glare sensitivity in patients with phakic and pseudophakic eyes

被引:23
作者
Eisenmann, D [1 ]
Jacobi, FK [1 ]
Dick, B [1 ]
Jacobi, KW [1 ]
Pabst, W [1 ]
机构
[1] INST MED INFORMAT,GIESSEN,GERMANY
关键词
contrast sensitivity; glare sensitivity; glare acuity; night driving ability; cataract; monofocal IOL; multifocal IOL;
D O I
10.1055/s-2008-1035175
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Background Glare disability and appearance of halos may be side-effects of cataract, but were also described in patients with multifocal IOLs. The aim of this study was to compare glare sensitivity and halo size in phakic and pseudophakic eyes. Patients and Methods Contrast sensitivity without and with glare and halos around a light source Were measured by means of a new computerized test in patients with cataract, monofocal IOLs, multizonal progressive and diffractive multifocal IOLs as well as in a younger control group of subjects with clear lenses. Glare acuity was measured at three different luminance settings. Results Patients with cataract showed the most important reduction in contrast sensitivity, noticed significantly larger halos and were more impaired in glare acuity than patients with monofocal or multizonal progressive IOLs. There was no significant difference in any criteria between these two pseudophakic groups. Subjects with a clear cristalline lens had statistically significant better results compared with all other groups. Conclusion An increase in glare sensitivity and the appearence of halos are more important in patients with even minor cataracts than in any pseudophakic population. As a consequence of this study, night driving ability should be carefully examined in any pseudophakic patient, but also in any subject with even beginning cataract.
引用
收藏
页码:87 / 92
页数:6
相关论文
共 30 条
[1]   CONTRAST AND GLARE SENSITIVITY IN PATIENTS WITH MULTIFOCAL IOLS - RESULTS 2 YEARS AFTER LENS IMPLANTATION [J].
AUFFARTH, GU ;
HUNOLD, W ;
BREITENBACH, S ;
WESENDAHL, TA ;
MEHDORN, E .
KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 1993, 203 (05) :336-340
[3]  
COUPLAND SG, 1981, CAN J OPHTHALMOL, V16, P136
[4]   THE ARRAY MULTIFOCAL IOL - CONCEPT AND CLINICAL-RESULTS [J].
EISENMANN, D ;
JACOBI, KW .
KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 1993, 203 (03) :189-194
[5]  
EISENMANN D, 1993, EUR J IMPLANT REFRAC, V5, P99
[6]   EXPLANATION OF 3M DIFFRACTIVE INTRAOCULAR LENSES [J].
ELLINGSON, FT .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1990, 16 (06) :697-702
[7]   CONTRAST ATTENUATION CHARACTERISTICS OF IRIS CLIPPED INTRAOCULAR-LENS IMPLANTS INSITU [J].
HESS, RF ;
WOO, GC ;
WHITE, PD .
BRITISH JOURNAL OF OPHTHALMOLOGY, 1985, 69 (02) :129-135
[8]   MULTIFOCAL INTRAOCULAR LENSES - STATE-OF-THE-ART [J].
HESSEMER, V ;
EISENMANN, D ;
JACOBI, KW .
KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 1993, 203 (01) :19-33
[9]  
Hessemer V., 1994, Ophthalmologe, V91, P465
[10]  
HESSEMER V, 1993, 6 K DGII, P255