Silver cluster interferences in matrix-assisted laser desorption/ionization (MALDI) mass spectrometry of nonpolar polymers

被引:55
作者
Macha, SF
Limbach, PA
Hanton, SD
Owens, KG
机构
[1] Louisiana State Univ, Dept Chem, Baton Rouge, LA 70803 USA
[2] Air Prod & Chem Inc, Allentown, PA 18195 USA
[3] Drexel Univ, Dept Chem, Philadelphia, PA 19104 USA
关键词
D O I
10.1016/S1044-0305(01)00225-2
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Potential difficulties associated with background silver salt clusters during matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) of nonpolar polymers are reported. Silver salt cluster ions were observed from m/z 1500 to 7000 when acidic, polar matrices, such as 2,5-dihydroxybenzoic acid (DHB), all-trans-retinoic acid (RTA) or 2-(4-hydroxyphenylazo)benzoic acid (HABA), were used for the analysis of nonpolar polymers. These background signals could be greatly reduced or eliminated by the use of nonpolar matrices such as anthracene or pyrene. Representative examples of these background interferences are demonstrated during the analysis of low molecular weight nonpolar polymers including polybutadiene and polystyrene. Nonpolar polymers analyzed with acidic, polar matrices (e.g., RTA) and silver cationization reagents can yield lower quality mass spectral results when interferences due to silver clusters are present. Replacing the polar matrices with nonpolar matrices or the silver salts with copper salts substantially improved the quality of the analytical results. In addition, it was found that silver contamination cannot be completely removed from standard stainless steel sample plates, although the presence of silver contamination was greatly reduced after thorough cleaning of the sample plate with aluminum oxide grit. Carry-over silver may cationize polymer samples and complicate the interpretation of data obtained using nonpolar matrices in the absence of added cationization reagents. (C) 2001 American Society for Mass Spectrometry.
引用
收藏
页码:732 / 743
页数:12
相关论文
共 20 条
[1]  
CORNETT L, 1998, P 46 ASMS C MASS SPE, P1058
[2]  
Danis PO, 1996, RAPID COMMUN MASS SP, V10, P862
[3]  
Deery MJ, 1997, RAPID COMMUN MASS SP, V11, P57, DOI 10.1002/(SICI)1097-0231(19970115)11:1<57::AID-RCM772>3.0.CO
[4]  
2-G
[5]  
Hanton S. D., 1998, P 46 ASMS C MASS SPE, P1185
[6]   Matrix-assisted laser desorption/ionization-collision induced dissociation of poly(styrene) [J].
Jackson, AT ;
Yates, HT ;
Scrivens, JH ;
Green, MR ;
Bateman, RH .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1998, 9 (04) :269-274
[7]  
Lehmann E, 1997, RAPID COMMUN MASS SP, V11, P1483, DOI 10.1002/(SICI)1097-0231(199709)11:14<1483::AID-RCM982>3.0.CO
[8]  
2-F
[9]  
Limbach PA, 1998, SPECTROSCOPY-US, V13, P16
[10]  
Liu HMD, 1996, RAPID COMMUN MASS SP, V10, P483