An 800-MeV proton radiography facility for dynamic experiments

被引:179
作者
King, NSP
Ables, E
Adams, K
Alrick, KR
Amann, JF
Balzar, S
Barnes, PD
Crow, ML
Cushing, SB
Eddleman, JC
Fife, TT
Flores, P
Fujino, D
Gallegos, RA
Gray, NT
Hartouni, EP
Hogan, GE
Holmes, VH
Jaramillo, SA
Knudsson, JN
London, RK
Lopez, RR
McDonald, TE
McClelland, JB
Merrill, FE
Morley, KB
Morris, CL
Naivar, FJ
Parker, EL
Park, HS
Pazuchanics, PD
Pillai, C
Riedel, CM
Sarracino, JS
Shelley, FE
Stacy, HL
Takala, BE
Thompson, R
Tucker, HE
Yates, GJ
Ziock, HJ
Zumbro, JD
机构
[1] Univ Calif Los Alamos Natl Lab, Los Alamos, NM 87545 USA
[2] Univ Calif Lawrence Livermore Natl Lab, Livermore, CA 94550 USA
[3] Bechtel Nevada, Los Alamos, NM 87545 USA
关键词
D O I
10.1016/S0168-9002(98)01241-8
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The capability has successfully been developed at the Los Alamos Nuclear Science Center (LANSCE) to utilize a spatially and temporally prepared 800 MeV proton beam to produce proton radiographs. A series of proton bursts are transmitted through a dynamic object and transported, via a unique magnetic lens system, to an image plane. The magnetic lens system permits correcting for the effects of multiple coulomb scattering which would otherwise completely blur the spatially transmitted information at the image plane. The proton radiographs are recorded either on a time integrating film plate or with a recently developed multi-frame electronic imaging camera system. The latter technique permits obtaining a time dependent series of proton radiographs with time intervals (modulo 358 ns) up to many microseconds and variable time intervals between images. One electronically shuttered, intensified, CCD camera is required per image. These cameras can detect single protons interacting with a scintillating fiber optic array in the image plane but also have a dynamic range which permits recording radiographs with better than 5% statistics for observation of detailed density variations in the object. A number of tests have been carried out to characterize the quality of the proton radiography system for absolute mass determination, resolution, and dynamic range. Initial dynamic experiments characterized the temporal and spatial behavior of shock propagation in a high explosive sample with up to six images per experiment. Based on experience with the prototype system, a number of upgrades an being implemented including the anticipated capability for enhanced mass discrimination through differential multiple coulomb scattering radiographs and more images with improved imaging techniques. (C) 1999 Published by Elsevier Science B.V. All rights reserved.
引用
收藏
页码:84 / 91
页数:8
相关论文
共 2 条
[1]  
MOTTERSHEAD CT, 1997, P PART ACC C VANC CA
[2]  
YATES GJ, 1998, P EL IM 98 C SAN JOS