Validity and reliability of the PowerTap mobile cycling powermeter when compared with the SRM device

被引:102
作者
Bertucci, W
Duc, S
Villerius, V
Pernin, JN
Grappe, F
机构
[1] Univ Reims, LACM, EA 3304, Reims 2, France
[2] Univ Franche Comte, UMR 6604, CNRS, Lab Mecan Appl, F-25030 Besancon, France
关键词
cycling; mobile powermeter; SRM system; power output; comparison;
D O I
10.1055/s-2005-837463
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
The SRM power measuring crank system is nowadays a popular device for cycling power output (PO) measurements in the field and in laboratories. The PowerTap (CycleOps, Madison, USA) is a more recent and less well-known device that allows mobile PO measurements of cycling via the rear wheel hub. The aim of this study is to test the validity and reliability of the PowerTap by comparing it with the most accurate (i.e. the scientific model) of the SRM system. The validity of the PowerTap is tested during i) sub-maximal incremental intensities (ranging from 100 to 420W) on a treadmill with different pedalling cadences (45 to 120 rpm) and cycling positions (standing and seated) on different grades, ii) a continuous sub-maximal intensity lasting 30 min, iii) a maximal intensity (8-s sprint), and iiii) real road cycling. The reliability is assessed by repeating ten times the submaximal incremental and continuous tests. The results show a good validity of the PowerTap during sub-maximal intensities between 100 and 450 W (mean PO difference -1.2 +/- 13 %) when it is compared to the scientific SRM model, but less validity for the maximal PO during sprint exercise, where the validity appears to depend on the gear ratio. The reliability of the PowerTap during the sub-maximal intensities is similar to the scientific SRM model (the coefficient of variation is respectively 0.9 to 2.9% and 0.7 to 2.1 % for PowerTap and SRM). The PowerTap must be considered as a suitable device for PO measurements during sub-maximal real road cycling and in sub-maximal laboratory tests.
引用
收藏
页码:868 / 873
页数:6
相关论文
共 20 条
[1]   Statistical methods for assessing measurement error (reliability) in variables relevant to sports medicine [J].
Atkinson, G ;
Nevill, AM .
SPORTS MEDICINE, 1998, 26 (04) :217-238
[2]   Validity and reliability of the axiom powertrain cycle ergometer when compared with an SRM powermeter [J].
Bertucci, W ;
Duc, S ;
Villerius, V ;
Grappe, F .
INTERNATIONAL JOURNAL OF SPORTS MEDICINE, 2005, 26 (01) :59-65
[3]  
BERTUCCI W, IN PRESS J SPORTS ME
[4]  
BIAND JM, 1986, LANCET, V1, P307
[5]   Crank inertial load has little effect on steady-state pedaling coordination [J].
Fregly, BJ ;
Zajac, FE ;
Dairaghi, CA .
JOURNAL OF BIOMECHANICS, 1996, 29 (12) :1559-1567
[6]   Aerodynamic drag in field cycling with special reference to the Obree's position [J].
Grappe, F ;
Candau, R ;
Belli, A ;
Rouillon, JD .
ERGONOMICS, 1997, 40 (12) :1299-1311
[7]   Influence of tyre pressure and vertical load on coefficient of rolling resistance and simulated cycling performance [J].
Grappe, F ;
Candau, R ;
Barbier, B ;
Hoffman, MD ;
Belli, A ;
Rouillon, JD .
ERGONOMICS, 1999, 42 (10) :1361-1371
[8]   Optimal pedalling velocity characteristics during maximal and submaximal cycling in humans [J].
Hintzy, F ;
Belli, A ;
Grappe, F ;
Rouillon, JD .
EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY AND OCCUPATIONAL PHYSIOLOGY, 1999, 79 (05) :426-432
[9]   Reliability of power in physical performance tests [J].
Hopkins, WG ;
Schabort, EJ ;
Hawley, JA .
SPORTS MEDICINE, 2001, 31 (03) :211-234
[10]  
Jones S., 1998, ENG SPORT, V3, P265