Validation of a voxel-based FE method for prediction of the uniaxial apparent modulus of human trabecular bone using macroscopic mechanical tests and nanoindentation

被引:115
作者
Chevalier, Yan [1 ]
Pahr, Dieter [1 ]
Allmer, Helga [1 ]
Charlebois, Mathieu [1 ]
Zysset, Philippe [1 ]
机构
[1] Vienna Univ Technol, Inst Lightweight Design & Struct Biomech, A-1040 Vienna, Austria
关键词
trabecular bone; apparent modulus; nanoindentation; micro-CT; finite element modelling;
D O I
10.1016/j.jbiomech.2007.05.004
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Assessment of the mechanical properties of trabecular bone is of major biological and clinical importance for the investigation of bone diseases, fractures and their treatments. Finite element (FE) methods are getting increasingly popular for quantifying the elastic and failure properties of trabecular bone. In particular, voxel-based FE methods have been previously used to calculate the effective elastic properties of trabecular micro structures. However, in most studies, bone tissue moduli were assumed or back-calculated to match the apparent elastic moduli from experiments, which often lead to surprisingly low values when compared to nanoindentation results. In this study, voxel-based FE analysis of trabecular bone is combined with physical measures of volume fraction, micro-CT (mu LCT) reconstructions, uniaxial mechanical tests and specimen-specific nanoindentation tests for proper validation of the method. Cylindrical specimens of cancellous bone were extracted from human femurs and their volume fraction determined with Archimede's method. Uniaxial apparent modulus of the specimens was measured with an improved tension-compression testing protocol that minimizes boundary artefacts. Their mu tCT reconstructions were segmented to match the measured bone volume fraction and used to create full-size voxel models with 30-45 mu m element size. For each specimen, linear isotropic elastic material properties were defined based on specific nanoindentation measurements of its embedded bone tissue. Linear FE analyses were finally performed to simulate the uniaxial mechanical tests. Additional parametric analyses were performed to evaluate the potential errors on the predicted apparent modulus arising from variations in segmentation threshold, tissue modulus, and the use of 125-mm(3) cubic sub-regions. The results demonstrate an excellent correspondence between experimental measures and FE predictions of uniaxial apparent modulus. In conclusion, the adopted voxel-based FE approach is found to be a robust method to predict the linear elastic properties of human cancellous bone, provided segmentation of the mu CT reconstructions is carefully calibrated, tissue modulus is known a priori and the entire region of interest is included in the analysis. (c) 2007 Elsevier Ltd. All rights reserved.
引用
收藏
页码:3333 / 3340
页数:8
相关论文
共 27 条
[1]   Comparison of the elastic and yield properties of human femoral trabecular and cortical bone tissue [J].
Bayraktar, HH ;
Morgan, EF ;
Niebur, GL ;
Morris, GE ;
Wong, EK ;
Keaveny, TM .
JOURNAL OF BIOMECHANICS, 2004, 37 (01) :27-35
[2]   Mechanisms of uniformity of yield strains for trabecular bone [J].
Bayraktar, HH ;
Keaveny, TM .
JOURNAL OF BIOMECHANICS, 2004, 37 (11) :1671-1678
[3]   CHANGES OF INTERSTITIAL BONE THICKNESS WITH AGE IN MEN AND WOMEN [J].
BIRKENHAGERFRENKEL, DH ;
NIGG, AL ;
HENS, CJJ ;
BIRKENHAGER, JC .
BONE, 1993, 14 (03) :211-216
[4]   Finite element models predict cancellous apparent modulus when tissue modulus is scaled from specimen CT-attenuation [J].
Bourne, BC ;
van der Meulen, MCH .
JOURNAL OF BIOMECHANICS, 2004, 37 (05) :613-621
[5]   STEREOLOGY AND HISTOGRAM ANALYSIS OF BACKSCATTERED ELECTRON IMAGES - AGE-CHANGES IN BONE [J].
BOYDE, A ;
ELLIOTT, JC ;
JONES, SJ .
BONE, 1993, 14 (03) :205-210
[6]   Stress distribution along broken fibres in polymer-matrix composites [J].
de Morais, AB .
COMPOSITES SCIENCE AND TECHNOLOGY, 2001, 61 (11) :1571-1580
[7]   Accuracy of cancellous bone volume fraction measured by micro-CT scanning [J].
Ding, M ;
Odgaard, A ;
Hvid, I .
JOURNAL OF BIOMECHANICS, 1999, 32 (03) :323-326
[8]   The accuracy of digital image-based finite element models [J].
Guldberg, RE ;
Hollister, SJ ;
Charras, GT .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1998, 120 (02) :289-295
[9]   The influence of microcomputed tomography threshold variations on the assessment of structural and mechanical trabecular bone properties [J].
Hara, T ;
Tanck, E ;
Homminga, J ;
Huiskes, R .
BONE, 2002, 31 (01) :107-109
[10]   Nanoindentation discriminates the elastic properties of individual human bone lamellae under dry and physiological conditions [J].
Hengsberger, S ;
Kulik, A ;
Zysset, P .
BONE, 2002, 30 (01) :178-184