Determination of sucralose in foods by HPLC

被引:16
作者
Kobayashi, C [1 ]
Nakazato, M [1 ]
Yamajima, Y [1 ]
Ohno, I [1 ]
Kawano, M [1 ]
Yasuda, K [1 ]
机构
[1] Tokyo Metropolitan Res Lab Publ Hlth, Tokyo 1690073, Japan
来源
JOURNAL OF THE FOOD HYGIENIC SOCIETY OF JAPAN | 2001年 / 42卷 / 02期
关键词
sucralose; HPLC; ion chromatography (IC); dialysis; solid-phase extraction;
D O I
10.3358/shokueishi.42.139
中图分类号
TS2 [食品工业];
学科分类号
0832 ;
摘要
A method for the determination of sucralose in various foods by RI-HPLC and ion chromatography with a pulsed amperometric detector (PAD-IC) was developed. Chopped or homogenized samples were packed into cellulose tubing with 0.01 mol/L hydrochloric acid containing 10% sodium chloride and were dialyzed against 0.01 mol/L hydrochloric acid for 24 hours. The dialyzate was passed through a Bond Elut ENV cartridge, and the cartridge was washed with 0.2 mol/L NaOH and water. Sucralose was eluted from the cartridge with methanol. The extract was taken to dryness in an evaporator and the residue was re-dissolved in water. Sucralose was separated on an Inertsil ODS-3V column with a mobile phase of acetonitrile-water (15:85) and an RI detector. It was also determined on a CarboPak PA1 column with a mobile phase of 100 mmol/L NaOH-75 mmol/L CH3COONa, using a PAD detector. The recoveries of sucralose from various kinds of foods spiked at 50 mug/g and 200 mug/g ranged from 88 similar to 105%. The detection limit in samples was 10 mug/g for RI-HPLC and 1 mug/g for PAD-IC.
引用
收藏
页码:139 / 143
页数:5
相关论文
共 6 条
[1]  
FUKUTOMI F, 1998, FFI J FOODS FOOD ING, V177, P22
[2]  
ICHIKI H, 1995, JPN J FOOD CHEM, V2, P119
[3]  
ITO Y, 1999, FFI J, V182, P35
[4]  
Kobayashi C, 1999, J FOOD HYG SOC JPN, V40, P166, DOI 10.3358/shokueishi.40.166
[5]  
LAWRENCE JF, 1988, J ASSOC OFF ANA CHEM, V71, P934
[6]   ANALYSIS AND STABILITY OF THE SWEETENER SUCRALOSE IN BEVERAGES [J].
QUINLAN, ME ;
JENNER, MR .
JOURNAL OF FOOD SCIENCE, 1990, 55 (01) :244-246