Assessment of ≥50% and <50% intracranial stenoses by transcranial color-coded duplex sonography

被引:208
作者
Baumgartner, RW
Mattle, HP
Schroth, G
机构
[1] Univ Zurich Hosp, Dept Neurol, CH-8091 Zurich, Switzerland
[2] Univ Hosp Bern, Dept Neurol, CH-3010 Bern, Switzerland
[3] Univ Hosp Bern, Dept Neuroradiol, CH-3010 Bern, Switzerland
关键词
anticoagulants; aspirin; stenosis; ultrasonography; transcranial;
D O I
10.1161/01.STR.30.1.87
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background and Purpose-A favorable risk-benefit ratio for warfarin compared with aspirin has been reported for the prevention of major vascular events in symptomatic greater than or equal to 50% intracranial stenoses. Transcranial color-coded duplex sonography (TCCS) criteria providing an accurate detection of greater than or equal to 50% and <50% stenoses of the anterior, middle, and posterior cerebral arteries and basilar and vertebral arteries were evaluated retrospectively with angiography used as the standard of reference. Methods-Prospectively collected TCCS, extracranial color-coded duplex sonography, and intra-arterial digital subtraction angiography data of 310 patients were reviewed. The patients had angiography for confirmation of symptomatic extracranial greater than or equal to 70% carotid stenoses, symptomatic stenoses (peak systolic velocity higher than the corresponding mean value +2 SDs of 104 normal subjects), and occlusions of the middle cerebral or basilar artery previously assessed by ultrasound. The sonographer was not aware of angiographic findings. Results-TCCS would have detected all 31 of greater than or equal to 50% intracranial stenoses with I false-positive and 35 of 38 <50% stenoses with 3 false-positives. One of 69 stenoses (1%) and 280 of 2741 normal arteries (10%) were missed because of inadequate insonation windows. The corresponding peak systolic velocity cutoffs for greater than or equal to 50%/<50% stenoses were greater than or equal to 155/greater than or equal to 120 cm/s (anterior cerebral artery), greater than or equal to 220/greater than or equal to 155 cm/s (middle cerebral artery), greater than or equal to 145/greater than or equal to 100 cm/s (posterior cerebral artery), greater than or equal to 140/greater than or equal to 100 cm/s (basilar artery), and greater than or equal to 120/greater than or equal to 90 cm/s (vertebral artery). Conclusions-TCCS may reliably assess greater than or equal to 50% and <50% basal cerebral artery narrowing and prove useful for noninvasive management of patients with symptomatic intracranial stenoses.
引用
收藏
页码:87 / 92
页数:6
相关论文
共 43 条
  • [1] INTRACRANIAL BLOOD-FLOW VELOCITIES IN ACUTE ISCHEMIC STROKE
    ALEXANDROV, AV
    BLADIN, CF
    NORRIS, JW
    [J]. STROKE, 1994, 25 (07) : 1378 - 1383
  • [2] [Anonymous], 1990, NEUROLOGY, V40, P680
  • [3] [Anonymous], 1983, Statistical methods
  • [4] CEREBROVASCULAR DISEASE .1. THE LARGE ARTERIES OF THE CIRCLE OF WILLIS
    BAKER, AB
    IANNONE, A
    [J]. NEUROLOGY, 1959, 9 (05) : 321 - 332
  • [5] Baumgartner RW, 1997, AM J NEURORADIOL, V18, P127
  • [6] A VALIDATION-STUDY ON THE INTRAOBSERVER REPRODUCTIBILITY OF TRANSCRANIAL COLOR-CODED DUPLEX SONOGRAPHY VELOCITY-MEASUREMENTS
    BAUMGARTNER, RW
    MATHIS, J
    STURZENEGGER, M
    MATTLE, HP
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 1994, 20 (03) : 233 - 237
  • [7] Diagnostic criteria for transcranial colour-coded duplex sonography evaluation of cross-flow through the circle of Willis in unilateral obstructive carotid artery disease
    Baumgartner, RW
    Baumgartner, I
    Schroth, G
    [J]. JOURNAL OF NEUROLOGY, 1996, 243 (07) : 516 - 521
  • [8] Contrast-enhanced transcranial color-coded duplex sonography in ischemic cerebrovascular disease
    Baumgartner, RW
    Arnold, M
    Gonner, F
    Staikow, I
    Herrmann, C
    Rivoir, A
    Muri, RM
    [J]. STROKE, 1997, 28 (12) : 2473 - 2478
  • [9] Comparative study of power-based versus mean frequency-based transcranial color-coded duplex sonography in normal adults
    Baumgartner, RW
    Schmid, C
    Baumgartner, I
    [J]. STROKE, 1996, 27 (01) : 101 - 104
  • [10] TRANSCRANIAL COLOR-CODED DUPLEX SONOGRAPHY IN CEREBRAL ANEURYSMS
    BAUMGARTNER, RW
    MATTLE, HP
    KOTHBAUER, K
    SCHROTH, G
    [J]. STROKE, 1994, 25 (12) : 2429 - 2434