Compact microelectrode array system: Tool for in situ monitoring of drug effects on neurotransmitter release from neural cells

被引:21
作者
Chen, Yu [1 ]
Guo, Chunxian [2 ]
Lim, Layhar [1 ]
Cheong, Serchoong [1 ]
Zhang, Qingxin [1 ]
Tang, Kumcheong [1 ]
Reboud, Julien [1 ]
机构
[1] Inst Microelect, Singapore 117685, Singapore
[2] Nanyang Technol Univ, Sch Chem, Sch Chem & Biomed Engn, Singapore, Singapore
关键词
D O I
10.1021/ac071182j
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Ibis paper presents a compact microelectrode array (MEA) system, to study potassium ion-induced dopamine release from PC12 neural cells, without relying on a micromanipulator and a microscope. The MEA chip was integrated with a custom-made "test jig", which provides a robust electrical interfacing tool between the microchip and the macroenvironment, together with a potentiostat and a microfluidic syringe pump. This integrated system significantly simplifies the operation procedures, enhances sensing performance, and reduces fabrication costs. The achieved detection limit for dopamine is 3.8 X 10(-2) mu M (signal/noise, S/N = 3) and the dopamine linear calibration range is up to 7.39 +/- 0.06 mu M (mean SE). The effects of the extracelluar matrix collagen coating of the microelectrodes on dopamine sensing behaviors, as well as the influences of K+ and L-3,4-digydroxyphenylalanine concentrations and incubation times on dopamine release, were extensively studied. The results show that our system is well suited for biologists to study chemical release from living cells as well as drug effects on secreting cells. The current system also shows a potential for further improvements toward a multichip array system for drug screening applications.
引用
收藏
页码:1133 / 1140
页数:8
相关论文
共 30 条
[1]   EFFECTS OF HIGH POTASSIUM ON THE RELEASE OF [H-3] DOPAMINE FROM THE CAT CAROTID-BODY INVITRO [J].
ALMARAZ, L ;
GONZALEZ, C ;
OBESO, A .
JOURNAL OF PHYSIOLOGY-LONDON, 1986, 379 :293-307
[2]   Microfabrication and microfluidics for tissue engineering: state of the art and future opportunities [J].
Andersson, H ;
van den Berg, A .
LAB ON A CHIP, 2004, 4 (02) :98-103
[3]  
BOWYER JF, 1990, J PHARMACOL EXP THER, V254, P664
[4]  
BOWYER JF, 1992, J PHARMACOL EXP THER, V261, P72
[5]   AMPEROMETRIC MONITORING OF STIMULATED CATECHOLAMINE RELEASE FROM RAT PHEOCHROMOCYTOMA (PC12) CELLS AT THE ZEPTOMOLE LEVEL [J].
CHEN, TK ;
LUO, GO ;
EWING, AG .
ANALYTICAL CHEMISTRY, 1994, 66 (19) :3031-3035
[6]   MATHEMATICAL-MODEL ON THE SENSING BEHAVIOR OF A BIOOXIDATION BIOSENSOR [J].
CHEN, Y ;
TAN, TC .
AICHE JOURNAL, 1995, 41 (04) :1025-1036
[7]  
CHEN Y, 2005, P SOC PHOTO-OPT INS, V6112
[8]   Microelectrode array biochip: Tool for in vitro drug screening based on the detection of a drug effect on dopamine release from PC12 cells [J].
Cui, Hui-Fang ;
Ye, Jian-Shan ;
Chen, Yu ;
Chong, Ser-Choong ;
Sheu, Fwu-Shan .
ANALYTICAL CHEMISTRY, 2006, 78 (18) :6347-6355
[9]   In situ temporal detection of dopamine exocytosis from L-dopa-incubated MN9D cells using microelectrode array-integrated biochip [J].
Cui, Hui-Fang ;
Ye, Jian-Shan ;
Chen, Yu ;
Chong, Ser-Choong ;
Liu, Xiao ;
Lim, Tit-Meng ;
Sheu, Fwu-Shan .
SENSORS AND ACTUATORS B-CHEMICAL, 2006, 115 (02) :634-641
[10]  
EUGENIA BS, 2002, J PHARMACOL EXP THER, V301, P953