Direct sensing of total acidity by chronopotentiometric flash titrations at polymer membrane ion-selective electrodes

被引:44
作者
Gemene, Kebede L. [1 ]
Bakker, Eric [1 ,2 ]
机构
[1] Purdue Univ, Dept Chem, W Lafayette, IN 47907 USA
[2] Curtin Univ Technol, Dept Appl Chem, Nanochem Res Inst, Perth, WA 6845, Australia
关键词
D O I
10.1021/ac701983x
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Polymer membrane ion-selective electrodes containing lipophilic ionophores are traditionally interrogated by zero current potentiometry, which, ideally, gives information on the sample activity of ionic species. It is shown here that a discrete cathodic current pulse across an H+-selective polymeric membrane doped with the ionophore ETH 5294 may be used for the chronopotentiometric detection of pH in well-buffered samples. However, a reduction in the buffer capacity leads to large deviations from the expected Nernstian response slope. This is explained by the local depletion of hydrogen ions at the sample-membrane interface as a result of the galvano-statically imposed ion flux in direction of the membrane. This depletion is found to be a function of the total acidity of the sample and can be directly monitored chronopotentiometrically in a flash titration experiment. The subsequent application of a baseline potential pulse reverses the extraction process of the current pulse, allowing one to interrogate the sample with minimal perturbation. In one protocol, total acidity is found to be proportional to the magnitude of applied current at the flash titration end point. More conveniently, the square root of the flash titration end point time observed at a fixed applied current is a linear function of the total acid concentration. This suggests that it is possible to perform rapid localized pH titrations at ion-selective electrodes without the need for volumetric titrimetry. The technique is explored here for acetic acid, MES and citric acid with promising results. Polymeric membrane electrodes based on poly(vinyl chloride) plasticized with o-nitrophenyl octyl ether in a 1:2 mass ratio may be used for the detection of acids of up to ca. 1 mM concentration, with flash titration times on the order of a few seconds. Possible limitations of the technique are discussed, including variations of the acid diffusion coefficients and influence of electrical migration.
引用
收藏
页码:3743 / 3750
页数:8
相关论文
共 58 条
[1]   NEUTRAL CARRIER BASED HYDROGEN-ION SELECTIVE MICROELECTRODE FOR EXTRACELLULAR AND INTRACELLULAR STUDIES [J].
AMMANN, D ;
LANTER, F ;
STEINER, RA ;
SCHULTHESS, P ;
SHIJO, Y ;
SIMON, W .
ANALYTICAL CHEMISTRY, 1981, 53 (14) :2267-2269
[2]   OPTIMUM COMPOSITION OF NEUTRAL CARRIER BASED PH ELECTRODES [J].
BAKKER, E ;
XU, AP ;
PRETSCH, E .
ANALYTICA CHIMICA ACTA, 1994, 295 (03) :253-262
[3]   SYNTHESIS AND CHARACTERIZATION OF NEUTRAL HYDROGEN ION-SELECTIVE CHROMOIONOPHORES FOR USE IN BULK OPTODES [J].
BAKKER, E ;
LERCHI, M ;
ROSATZIN, T ;
RUSTERHOLZ, B ;
SIMON, W .
ANALYTICA CHIMICA ACTA, 1993, 278 (02) :211-225
[4]   Ion-selective electrodes based on two competitive ionophores for determining effective stability constants of ion-carrier complexes in solvent polymer membranes [J].
Bakker, E ;
Pretsch, E .
ANALYTICAL CHEMISTRY, 1998, 70 (02) :295-302
[5]  
BARD AJ, 2001, ELECTROCHEMICAL METH, V7, P255
[6]   Thirty years of ISFETOLOGY - What happened in the past 30 years and what may happen in the next 30 years [J].
Bergveld, P .
SENSORS AND ACTUATORS B-CHEMICAL, 2003, 88 (01) :1-20
[7]   Selective coulometric release of ions from ion selective polymeric membranes for calibration-free titrations [J].
Bhakthavatsalam, Vishnupriya ;
Shvarev, Alexey ;
Bakker, Eric .
ANALYST, 2006, 131 (08) :895-900
[8]   Carrier-based ion-selective electrodes and bulk optodes. 2. Ionophores for potentiometric and optical sensors [J].
Buhlmann, P ;
Pretsch, E ;
Bakker, E .
CHEMICAL REVIEWS, 1998, 98 (04) :1593-1687
[9]   Effects of nanofiltration on trihalomethane and haloacetic acid precursor removal and speciation in waters containing low concentrations of bromide ion [J].
Chellam, S .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2000, 34 (09) :1813-1820
[10]   STEADY-STATE VOLTAMMETRY OF STRONG AND WEAK ACIDS WITH AND WITHOUT SUPPORTING ELECTROLYTE [J].
CISZKOWSKA, M ;
STOJEK, Z ;
MORRIS, SE ;
OSTERYOUNG, JG .
ANALYTICAL CHEMISTRY, 1992, 64 (20) :2372-2377