Optical fiber immunosensor based on a poly(pyrrole-benzophenone) film for the detection of antibodies to viral antigen

被引:73
作者
Konry, T
Novoa, A
Shemer-Avni, Y
Hanuka, N
Cosnier, S
Lepellec, A
Marks, RS
机构
[1] Ben Gurion Univ Negev, Natl Inst Biotechnol Negev, IL-84105 Beer Sheva, Israel
[2] Ben Gurion Univ Negev, Fac Engn Sci, Dept Biotechnol Engn, IL-84105 Beer Sheva, Israel
[3] Ben Gurion Univ Negev, Fac Hlth Sci, Dept Virol, IL-84105 Beer Sheva, Israel
[4] Univ Grenoble 1, Lab Electrochim Organ & Photochim Redox, CNRS, UMR 5630, F-38041 Grenoble, France
关键词
D O I
10.1021/ac048569w
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We describe herein a newly developed optical microbiosensor for the diagnosis of hepatitis C virus (HCV) by using a novel photoimmobilization methodology based on a photoactivable electrogenerated polymer film deposited upon surface-conductive fiber optics, which are then used to link a biological receptor to the fiber tip through light mediation. This fiber-optic electroconductive surface modification is done by the deposition of a thin layer of indium tin oxide on the silica surface of the fiber optics. Monomers are then electropolymerized onto the conductive metal oxide surface; thereafter, the fibers are immersed in a solution containing HCV-E2 envelope protein antigen and illuminated with UV light (wavelength similar to 345 nm). As a result of the photochemical reaction, a thin layer of the antigen becomes covalently bound to the benzophenone-modified surface. The photochemically modified fiber optics were tested as immunosensors for the detection of anti-E2 protein antibody analyte that was measured through chemiluminescence reaction. The biosensor was tested for sensitivity, specificity, and overall practicality. Our results suggest that the detection of anti-E2 antibodies with this microbiosensor may enhance significantly HCV serological standard testing especially among patients during dialysis, which were diagnosed as HCV negative, by standard immunological tests, but were known to carry the virus. If transformed into an easy to use procedure, this assay might be used in the future as an important clinical tool for HCV screening in blood banks.
引用
收藏
页码:1771 / 1779
页数:9
相关论文
共 22 条
[1]   Electrochemical synthesis of adherent polypyrrole films on zinc electrodes in acidic and neutral organic media [J].
Bazzaoui, M ;
Bazzaoui, EA ;
Martins, L ;
Martins, JI .
SYNTHETIC METALS, 2002, 128 (01) :103-114
[2]   A fluorescent radioiodinated oligonucleotidic photoaffinity probe for protein labeling: Synthesis and photolabeling of thrombin [J].
Berens, C ;
Courtoy, PJ ;
Sonveaux, E .
BIOCONJUGATE CHEMISTRY, 1999, 10 (01) :56-61
[3]   An electrogenerated poly(pyrrole-benzophenone) film for the photografting of proteins [J].
Cosnier, S ;
Senillou, A .
CHEMICAL COMMUNICATIONS, 2003, (03) :414-415
[4]   Electrochemical deposition of polypyrrole films on organosilane-modified ITO substrates [J].
Cossement, D ;
Plumier, F ;
Delhalle, J ;
Hevesi, L ;
Mekhalif, Z .
SYNTHETIC METALS, 2003, 138 (03) :529-536
[5]   FUNCTIONALIZED POLYPYRROLES - NEW MOLECULAR MATERIALS FOR ELECTROCATALYSIS AND RELATED APPLICATIONS [J].
DERONZIER, A ;
MOUTET, JC .
ACCOUNTS OF CHEMICAL RESEARCH, 1989, 22 (07) :249-255
[6]   BENZOPHENONE PHOTOPHORES IN BIOCHEMISTRY [J].
DORMAN, G ;
PRESTWICH, GD .
BIOCHEMISTRY, 1994, 33 (19) :5661-5673
[7]  
FLEMING SA, 1995, TETRAHEDRON, V51, P12479
[8]  
FREEMAN T M, 1978, Analytical Chemistry, V50, P1242, DOI 10.1021/ac50031a012
[9]   Hepatitis C virus infection in renal failure patients in the absence of anti-hepatitis C virus antibodies [J].
Hanuka, N ;
Sikuler, E ;
Tovbin, D ;
Mostoslavsky, M ;
Hausman, M ;
Orgel, M ;
Yaari, A ;
Shemer-Avni, Y .
JOURNAL OF VIRAL HEPATITIS, 2002, 9 (02) :141-145
[10]  
Hanuka N., 2004, J MED VIROL, V9999, P1