Accurate and Less-Disturbing Active Antiislanding Method Based on PLL for Grid-Connected Converters

被引:128
作者
Ciobotaru, Mihai [1 ]
Agelidis, Vassilios G. [2 ]
Teodorescu, Remus [1 ]
Blaabjerg, Frede [1 ]
机构
[1] Aalborg Univ, Inst Energy Technol, DK-9220 Aalborg, Denmark
[2] Univ Sydney, Sch Elect & Informat Engn, Sydney, NSW 2006, Australia
关键词
Antiislanding; grid-connected converters; inverters; photovoltaics; FREQUENCY-SHIFT METHOD; PERFORMANCE ASSESSMENT; IMPEDANCE ESTIMATION; PREVENTION; PROTECTION; INVERTER;
D O I
10.1109/TPEL.2010.2040088
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
An accurate and less-disturbing active antiislanding method suitable for grid-connected converters using phase-locked loop (PLL) based grid synchronization is proposed in this paper. The orthogonal signal generator required by a single-phase PLL is built using a second-order generalized integrator. The inverter current reference is slightly modified each output cycle by an injected signal, and a feedback signal is extracted from the voltage of the point of common coupling (PCC). When the grid becomes unavailable, the feedback signal moves outside of a preset threshold value. The disturbance caused by this method is small compared to other active antiislanding methods, such as active frequency drift or frequency shift up/down. The method does not affect the zero crossing of the injected current, can be used to estimate the grid impedance, and is highly robust to different grid disturbances and stiffness. The performance of the proposed method has been studied through extensive simulations using MATLAB/Simulink and experiments. Selected results are presented to confirm its validity.
引用
收藏
页码:1576 / 1584
页数:9
相关论文
共 41 条
[1]  
[Anonymous], 617272002 IEC
[2]  
[Anonymous], 2002, 3591 SAND
[3]  
[Anonymous], 2006, Automatic Disconnection Device between a Generator and the Public Low-Voltage Grid
[4]  
[Anonymous], P IEEE APEC
[5]   A digital controlled PV-inverter with grid impedance estimation for ENS detection [J].
Asiminoaei, L ;
Teodorescu, R ;
Blaabjerg, F ;
Borup, U .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2005, 20 (06) :1480-1490
[6]   Implementation and test of an online embedded grid impedance estimation technique for PV inverters [J].
Asiminoaei, L ;
Teodorescu, R ;
Blaabjerg, F ;
Borup, U .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2005, 52 (04) :1136-1144
[7]   Accurate and Less-Disturbing Active Anti-Islanding Method based on PLL for Grid-Connected PV Inverters [J].
Ciobotaru, M. ;
Agelidis, V. ;
Teodorescu, R. .
2008 IEEE POWER ELECTRONICS SPECIALISTS CONFERENCE, VOLS 1-10, 2008, :4569-+
[8]   Online grid impedance estimation for single-phase grid-connected systems using PQ variations [J].
Ciobotaru, Mihai ;
Teodorescu, Remus ;
Rodriguez, Pedro ;
Timbus, Adrian ;
Blaabjerg, Frede .
2007 IEEE POWER ELECTRONICS SPECIALISTS CONFERENCE, VOLS 1-6, 2007, :2306-2312
[9]   On-line grid impedance estimation based on harmonic injection for grid-connected PV inverter [J].
Ciobotaru, Mihai ;
Teodorescu, Remus ;
Blaabjerg, Frede .
2007 IEEE INTERNATIONAL SYMPOSIUM ON INDUSTRIAL ELECTRONICS, PROCEEDINGS, VOLS 1-8, 2007, :2437-+
[10]   A new single-phase PLL structure based on second order generalized integrator [J].
Ciobotaru, Mihai ;
Teodorescu, Remus ;
Blaabjerg, Frede .
2006 IEEE POWER ELECTRONICS SPECIALISTS CONFERENCE, VOLS 1-7, 2006, :361-+