A solid phase extraction method for determination of nicotine in serum and urine by isotope dilution gas chromatography mass spectrometry with selected ion monitoring

被引:17
作者
Baskin, LB
Anderson, RW
Charlson, JR
Hurt, RD
Lawson, GM
机构
[1] Univ Texas, SW Med Ctr, Dept Pathol, Dallas, TX 75235 USA
[2] Mayo Clin & Mayo Fdn, Nicotine Res Ctr, Rochester, MN 55905 USA
[3] Mayo Clin & Mayo Fdn, Dept Lab Med, Rochester, MN 55905 USA
[4] Mayo Clin & Mayo Fdn, Dept Pathol, Rochester, MN 55905 USA
关键词
serum nicotine; urine nicotine;
D O I
10.1177/000456329803500406
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
A rapid method for measuring nicotine concentration in serum and urine is described. Deuterated nicotine is used as an internal standard. Nicotine and deuterated nicotine are extracted using a copolymeric-bonded phase silica column. The extract is analysed by gas chromatography coupled with mass spectrometry (GC/MS) operating in selected ion monitoring mode. The method has a lower limit of detection of approximately 2 mu g/L and is linear to at least 2000 mu g/L. Within-run percentage coefficients of variation (% CV) are <4 in both assays over a nicotine concentration range of 10-2000 mu g/L. Between-run %CV in the serum assay are 5.4, 5.2, 4.8 and 5.9, respectively, at nicotine concentrations of 10, 15, 25, and 50 mu g/L. Between-run %CV in the urine assay are 5.9, 4.5, 2.7 and 5.2, respectively, at nicotine concentrations of 100, 250, 500, and 2000 mu g/L. The absolute recovery of nicotine is 61+/-6% (mean+/-SD) over the range of 10-250 mu g/L. The assay has been used to measure serum nicotine concentrations and 24-h urinary excretion of nicotine to monitor the extent of replacement in subjects receiving transdermal nicotine therapy for smoking cessation.
引用
收藏
页码:522 / 527
页数:6
相关论文
共 26 条
[1]   TRANSDERMAL DELIVERY OF NICOTINE IN NORMAL HUMAN VOLUNTEERS - A SINGLE DOSE AND MULTIPLE DOSE STUDY [J].
BANNON, YB ;
CORISH, J ;
CORRIGAN, OI ;
DEVANE, JG ;
KAVANAGH, M ;
MULLIGAN, S .
EUROPEAN JOURNAL OF CLINICAL PHARMACOLOGY, 1989, 37 (03) :285-290
[2]  
BARLOW RD, 1987, J CHROMATOGR-BIOMED, V419, P375
[3]  
BENOWITZ NL, 1988, NEW ENGL J MED, V319, P1318
[4]   PLASMA NICOTINE LEVELS AFTER INHALATION OF AEROSOLIZED NICOTINE [J].
BURCH, SG ;
ERBLAND, ML ;
GANN, LP ;
HILLER, FC .
AMERICAN REVIEW OF RESPIRATORY DISEASE, 1989, 140 (04) :955-957
[5]   SIMULTANEOUS DETERMINATION OF NICOTINE AND COTININE IN PLASMA USING CAPILLARY COLUMN GAS-CHROMATOGRAPHY WITH NITROGEN-SENSITIVE DETECTION [J].
CURVALL, M ;
KAZEMIVALA, E ;
ENZELL, CR .
JOURNAL OF CHROMATOGRAPHY, 1982, 232 (02) :283-293
[6]  
DAVIS RA, 1986, J CHROMATOGR SCI, V24, P134, DOI 10.1093/chromsci/24.4.134
[7]   CAPILLARY-COLUMN COMBINED GAS CHROMATOGRAPHY-MASS SPECTROMETRY METHOD FOR ESTIMATION OF NICOTINE IN PLASMA BY SELECTIVE ION MONITORING [J].
DOW, J ;
HALL, K .
JOURNAL OF CHROMATOGRAPHY, 1978, 153 (02) :521-525
[8]  
EMBER LR, 1994, CHEM ENG NEWS 1128, P8
[9]   DETERMINATION OF NICOTINE IN BIOLOGICAL-FLUIDS AT PICOGRAM LEVELS BY SELECTED ION RECORDING [J].
GRUENKE, LD ;
BEELEN, TC ;
CRAIG, JC ;
PETRAKIS, NL .
ANALYTICAL BIOCHEMISTRY, 1979, 94 (02) :411-416
[10]  
HARIHARAN M, 1988, CLIN CHEM, V34, P724