How sensitive to clinical change are ETDRS logMAR visual acuity measurements?

被引:179
作者
Rosser, DA
Cousens, SN
Murdoch, IE
Fitzke, FW
Laidlaw, DAH
机构
[1] UCL, Inst Ophthalmol, Dept Epidemiol & Int Eye Hlth, London EC1V 9EL, England
[2] Moorfields Eye Hosp, London, England
[3] London Sch Hyg & Trop Med, London WC1, England
[4] St Thomas Hosp, London, England
关键词
D O I
10.1167/iovs.02-1100
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE. To determine the sensitivity to change and specificity achieved when published test-retest variability (TRV) data are used to determine whether measured changes in ETDRS logarithm of the minimum angle of resolution (logMAR) visual acuity reflect true clinical change or are attributable to measurement error alone. METHODS. Various degrees of change in visual acuity were simulated in a group of normal subjects by adjusting test difficulty through manipulation of viewing distance. Sensitivity to simulated change and specificity were determined with change criteria derived from published Bland-Altman 95% ranges for TRV. RESULTS. The relationship between viewing distance and measured acuity was as predicted theoretically. Simulated acuity change of 0.2 logMAR (two lines of letters) or greater can be reliably distinguished from no change (both sensitivity and specificity >95%) with the ETDRS chart, but a change of 0.1 logMAR or less cannot. CONCLUSIONS. The use of 95% ranges for TRV to establish the smallest measured visual acuity change that can be reliably detected ensures a high specificity but does not take account of sensitivity. Use of change criteria derived from published 95% ranges results in a sensitivity of approximately 50% (assuming identical levels of TRV). Sensitivity may be improved by using a change criterion that is smaller than the minimum change sought, providing the change criterion is still at least as large as the 95% range for TRV, so that specificity is maintained. Reducing TRV allows smaller changes in acuity to be reliably detected.
引用
收藏
页码:3278 / 3281
页数:4
相关论文
共 16 条
[1]  
[Anonymous], PRACTICAL STAT MED R
[2]  
ARDITI A, 1993, INVEST OPHTH VIS SCI, V34, P120
[3]  
BAILEY IL, 1991, INVEST OPHTH VIS SCI, V32, P422
[4]  
BAILEY IL, 1976, AM J OPTOM PHYS OPT, V53, P740
[5]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[6]   REPEATED VISUAL-ACUITY MEASUREMENT - ESTABLISHING THE PATIENTS OWN CRITERION FOR CHANGE [J].
BROWN, B ;
LOVIEKITCHIN, J .
OPTOMETRY AND VISION SCIENCE, 1993, 70 (01) :45-53
[7]  
Committee on Vision, 1980, Advanced Ophthalmology, V41, P103
[8]   THE USE OF ACCURATE VISUAL-ACUITY MEASUREMENTS IN CLINICAL ANTI-CATARACT FORMULATION TRIALS [J].
ELLIOTT, DB ;
SHERIDAN, M .
OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 1988, 8 (04) :397-401
[9]   NEW VISUAL-ACUITY CHARTS FOR CLINICAL RESEARCH [J].
FERRIS, FL ;
KASSOFF, A ;
BRESNICK, GH ;
BAILEY, I .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1982, 94 (01) :91-96
[10]   VALIDITY AND RELIABILITY OF VISUAL-ACUITY MEASUREMENTS [J].
LOVIEKITCHIN, JE .
OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 1988, 8 (04) :363-370