Automatic post-implant needle reconstruction algorithm to characterize and improve implant robustness analyses

被引:10
作者
Archambault, L
Beaulieu, L
Tubic, D
机构
[1] Hop Hotel Dieu, Dept Radiooncol, Quebec City, PQ G1R 2J6, Canada
[2] Hop Hotel Dieu, Ctr Rech Cancerol, Quebec City, PQ G1R 2J6, Canada
[3] Univ Laval, Dept Phys Genie Phys & Opt, Quebec City, PQ, Canada
关键词
prostate brachytherapy; needle reconstruction; post-implant; seed misplacement; seed migration;
D O I
10.1118/1.1617480
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 [临床医学]; 100207 [影像医学与核医学]; 1009 [特种医学];
摘要
Post-implant analysis in permanent implant brachytherapy is an important process that provides a feedback on treatment quality. Random seed movements, edema, and needle related factors contribute to deteriorate dose coverage. For a complete study of these movements, it is important to reconstruct the post-implant seeds clusters but, up to now, this task was only possible via a long and difficult manual process. To facilitate post-implant analysis a simulated annealing algorithm was developed to perform automatic reconstructions. This process is fast (30-60 s on a 1.3 GHz pentium) and has a high level of success, even with up to 5% of seed loss. Tests on 21 clinical cases show that the algorithm yields exactly the same results as manual reconstructions. A realistic simulation tool was used to generate 58 synthetic post-implant data, in which cases the exact configuration was known. Even if some errors were found, pertinent information was extracted. For medium seed density [corresponding to seeds of 0.6 mCi (0.762 U)], 97% of seeds are matched with their correct needle and 89% are matched with their correct planned position. This method provides pertinent information that can be used to understand inhomogenous dose coverage in specific prostate quadrants; to make realistic post-implant simulations or to identify seeds belonging to a needle loaded with different seed types or activity. (C) 2003 American Association of Physicists in Medicine.
引用
收藏
页码:2897 / 2903
页数:7
相关论文
共 19 条
[1]
Archambault L, 2002, MED PHYS, V29, P1357
[2]
Comparison of seed loading approaches in prostate brachytherapy [J].
Butler, WM ;
Merrick, GS ;
Lief, JH ;
Dorsey, AT .
MEDICAL PHYSICS, 2000, 27 (02) :381-392
[3]
KIRKPATRICK CD, 1983, SCIENCE, V33, P671
[4]
Organ motion and its management [J].
Langen, KM ;
Jones, DTL .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2001, 50 (01) :265-278
[5]
On the determination of an effective planning volume for permanent prostate implants [J].
Lee, EK ;
Zaider, M .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2001, 49 (04) :1197-1206
[6]
Seed fixity in the prostate/periprostatic region following brachytherapy [J].
Merrick, GS ;
Butler, WM ;
Dorsey, AT ;
Lief, JH ;
Benson, ML .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2000, 46 (01) :215-220
[7]
The combined use of the natural and the cumulative dose-volume histograms in planning and evaluation of permanent prostatic seed implants [J].
Moerland, MA ;
van der Laarse, R ;
Luthmann, RW ;
Wijrdeman, HK ;
Battermann, JJ .
RADIOTHERAPY AND ONCOLOGY, 2000, 57 (03) :279-284
[8]
The American Brachytherapy Society recommendations for permanent prostate brachytherapy postimplant dosimetric analysis [J].
Nag, S ;
Bice, W ;
DeWyngaery, K ;
Prestidge, B ;
Stock, R ;
Yu, Y .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2000, 46 (01) :221-230
[9]
Optimization of permanent I-125 prostate implants using fast simulated annealing [J].
Pouliot, J ;
Tremblay, D ;
Roy, J ;
Filice, S .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1996, 36 (03) :711-720
[10]
Comparison of simulated annealing algorithms for conformal therapy treatment planning [J].
Rosen, II ;
Lam, KS ;
Lane, RG ;
Langer, M ;
Morrill, SM .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1995, 33 (05) :1091-1099