An empirical validation of the daylighting algorithms and associated interactions in building energy simulation programs using various shading devices and windows

被引:97
作者
Loutzenhiser, Peter G.
Maxwell, Gregory M.
Manz, Heinrich
机构
[1] Swiss Fed Labs Mat Testing & Res EMPA, Lab Bldg Technol, CH-8600 Dubendorf, Switzerland
[2] Iowa State Univ, Dept Mech Engn, Ames, IA 50011 USA
关键词
daylighting; empirical validation; building energy simulation tools;
D O I
10.1016/j.energy.2007.02.005
中图分类号
O414.1 [热力学];
学科分类号
摘要
Empirical validation of building energy simulation programs is an important technique in examining the effectiveness and accuracies of implemented algorithms. In recent years, daylighting algorithms incorporated in building energy simulation programs have become increasingly sophisticated in their abilities to predict the illuminance, light power reductions, and the associated thermal load interactions. The focus of this study was to examine measured and simulated light levels in an actual building constructed for research purposes. Daylighting models were constructed in EnergyPlus and DOE-2.1E and the predicted illuminance and light power were compared with measurements; an assessment of heating. and cooling interactions using a variable-air-volume reheat (VAVRH) system was also performed by analyzing reheat coil powers for the VAV boxes. The average differences from EnergyPlus for reference point daylight illuminance, light power, and reheat coil power predictions were within 119.2%, 16.9%, and 17.3%, respectively. DOE-2.1E predicted reference point daylight illuminances were within 114.1%, light powers were within 26.3%, and reheat coil power were within 25.4%. (c) 2007 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1855 / 1870
页数:16
相关论文
共 38 条
[1]
[Anonymous], 1996, 6946 EN ISO
[2]
De-Light: a software tool for the evaluation of direct daylighting illuminances both indoors and outdoors - comparison with Superlite 2.0 and Lumen Micro 7.1. [J].
Bellia, L ;
Cesarano, A ;
Minichiello, F ;
Sibilio, S .
BUILDING AND ENVIRONMENT, 2000, 35 (04) :281-295
[3]
Global energy savings in offices buildings by the use of daylighting [J].
Bodart, M ;
De Herde, A .
ENERGY AND BUILDINGS, 2002, 34 (05) :421-429
[4]
Clark G., 1978, PROC 2 NATL PASSIV S, P675
[5]
*ENERGYPLUS, 2005, ENG REF
[6]
*EUR COMM STAND, 1998, 410 EN
[7]
DAYLIGHTING ANALYSIS FOR CLASSROOMS USING DOE-2.1B [J].
GATES, S ;
WILCOX, J .
ENERGY AND BUILDINGS, 1984, 6 (04) :331-341
[8]
*GLAD SOFTW, 2002, SWISS FED LAB MAT TE
[9]
Gleser LJ, 1998, STAT SCI, V13, P277
[10]
Daylighting with external shading devices: design and simulation algorithms [J].
Gugliermetti, F ;
Bisegna, F .
BUILDING AND ENVIRONMENT, 2006, 41 (02) :136-149