Detection and correction of frequency instabilities for volumetric 1H echo-planar spectroscopic imaging

被引:63
作者
Ebel, A [1 ]
Maudsley, AA [1 ]
机构
[1] Univ Miami, Sch Med, Dept Radiol, Miami, FL USA
关键词
in vivo MR spectroscopic imaging; brain; instrumental instabilities; frequency drift; EPSI;
D O I
10.1002/mrm.20367
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Spectral quality in H-1 magnetic resonance spectroscopic imaging (MRSI) critically depends on the stability of the main magnetic field. For echo-planar MRSI implemented at 3 T, temperature variation in the passive steel shims of the magnet system can lead to a significant drift in the resonance frequency. A method is presented that incorporates interleaved measurement of the instantaneous resonance frequency of a reference water signal into a volumetric MRSI sequence and allows correction for the drift during postprocessing. Results from normal human brain at 3 T indicate that the correction largely removes lineshape distortions, recovers metabolite signal loss, and improves spectral quality by reducing the width of spectral lines; however, particularly in inferior regions, other sources of distortion may be present that cause broadening of spectral lines. (C) 2005 Wiley-Liss, Inc.
引用
收藏
页码:465 / 469
页数:5
相关论文
共 8 条
[1]   Improved spectral quality for 3D MR spectroscopic imaging using a high spatial resolution acquisition strategy [J].
Ebel, A ;
Maudsley, AA .
MAGNETIC RESONANCE IMAGING, 2003, 21 (02) :113-120
[2]   Assessment of 3D proton MR echo-planar spectroscopic imaging using automated spectral analysis [J].
Ebel, A ;
Soher, BJ ;
Maudsley, AA .
MAGNETIC RESONANCE IN MEDICINE, 2001, 46 (06) :1072-1078
[3]  
Henry PG, 1999, MAGN RESON MED, V42, P636, DOI 10.1002/(SICI)1522-2594(199910)42:4<636::AID-MRM4>3.0.CO
[4]  
2-I
[5]   Frame-by-frame PRESS 1H-MRS of the brain at 3 T:: The effects of physiological motion [J].
Katz-Brull, R ;
Lenkinski, RE .
MAGNETIC RESONANCE IN MEDICINE, 2004, 51 (01) :184-187
[6]   MOTION ARTIFACT COMPENSATION IN H-1 SPECTROSCOPIC IMAGING BY SIGNAL TRACKING [J].
POSSE, S ;
CUENOD, CA ;
LEBIHAN, D .
JOURNAL OF MAGNETIC RESONANCE SERIES B, 1993, 102 (02) :222-227
[7]   Automated spectral analysis -: III:: Application to in vivo proton MR spectroscopy and spectroscopic imaging [J].
Soher, BJ ;
Young, K ;
Govindaraju, V ;
Maudsley, AA .
MAGNETIC RESONANCE IN MEDICINE, 1998, 40 (06) :822-831
[8]   Phase coherent averaging in magnetic resonance Spectroscopy using interleaved navigator scans: Compensation of motion artifacts and magnetic field instabilities [J].
Thiel, T ;
Czisch, M ;
Elbel, GK ;
Hennig, F .
MAGNETIC RESONANCE IN MEDICINE, 2002, 47 (06) :1077-1082