A study of statistical error in isothermal titration calorimetry

被引:52
作者
Tellinghuisen, J [1 ]
机构
[1] Vanderbilt Univ, Dept Chem, Nashville, TN 37235 USA
关键词
ITC; data analysis; monlinear least squares; Monte Carlo; statistical errors;
D O I
10.1016/S0003-2697(03)00406-8
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In isothermal titration calorimetry (ITC), the two main sources of random (statistical) error are associated with the extraction of the heat q from the measured temperature changes and with the delivery of metered volumes of titrant. The former leads to uncertainty that is approximately constant and the latter to uncertainty that is proportional to q. The role of these errors in the analysis of ITC data by nonlinear least squares is examined for the case of 1:1 binding, M + X reversible arrow MX. The standard errors in the key parameters-the equilibrium constant Kdegrees and the enthalpy DeltaHdegrees-are assessed from the variance-covariance matrix computed for exactly fitting data. Monte Carlo calculations confirm that these "exact" estimates will normally suffice and show further that neglect of weights in the nonlinear fitting can result in significant loss of efficiency. The effects of the titrant volume error are strongly dependent on assumptions about the nature of this error: If it is random in the integral volume instead of the differential volume, correlated least-squares is required for proper analysis, and the parameter standard errors decrease with increasing number of titration steps rather than increase. (C) 2003 Elsevier Inc. All rights reserved.
引用
收藏
页码:79 / 88
页数:10
相关论文
共 19 条
[1]   LEAST-SQUARES EQUIVALENCE OF DIFFERENT REPRESENTATIONS OF ROTATIONAL CONSTANTS [J].
ALBRITTON, DL ;
SCHMELTEKOPF, AL ;
TELLINGHUISEN, J ;
ZARE, RN .
JOURNAL OF MOLECULAR SPECTROSCOPY, 1974, 53 (02) :311-314
[2]  
ALBRITTON DL, 1976, MOL SPECTROSCOPY MOD, V2, P1
[3]  
Bevington R., 1969, DATA REDUCTION ERROR
[5]   Thermodynamics of metal ion binding. 1. Metal ion binding by wild-type carbonic anhydrase [J].
DiTusa, CA ;
Christensen, T ;
McCall, KA ;
Fierke, CA ;
Toone, EJ .
BIOCHEMISTRY, 2001, 40 (18) :5338-5344
[6]   ANALYSIS OF PARAMETER RESOLUTION FROM DERIVATIVES OF BINDING ISOTHERMS [J].
DOYLE, ML ;
SIMMONS, JH ;
GILL, SJ .
BIOPOLYMERS, 1990, 29 (8-9) :1129-1135
[7]   Measurement of biochemical affinities with a Gill titration calorimeter [J].
ElHarrous, M ;
ParodyMorreale, A .
ANALYTICAL BIOCHEMISTRY, 1997, 254 (01) :96-108
[8]   DESCRIPTION OF A NEW GILL TITRATION CALORIMETER FOR THE STUDY OF BIOCHEMICAL REACTIONS .2. OPERATIONAL CHARACTERIZATION OF THE INSTRUMENT [J].
ELHARROUS, M ;
MAYORGA, OL ;
PARODYMORREALE, A .
MEASUREMENT SCIENCE AND TECHNOLOGY, 1994, 5 (09) :1071-1077
[9]   DESCRIPTION OF A NEW GILL TITRATION CALORIMETER FOR THE STUDY OF BIOCHEMICAL REACTIONS .1. ASSEMBLY AND BASIC RESPONSE OF THE INSTRUMENT [J].
ELHARROUS, M ;
GILL, SJ ;
PARODYMORREALE, A .
MEASUREMENT SCIENCE AND TECHNOLOGY, 1994, 5 (09) :1065-1070
[10]  
HAMILTON WC, 1964, STAT PHYSICAL SCI ES