Physics of thermionic dispenser cathode aging

被引:53
作者
Longo, RT [1 ]
机构
[1] Boeing Electron Dynam Devices Inc, Torrance, CA 90509 USA
关键词
D O I
10.1063/1.1621728
中图分类号
O59 [应用物理学];
学科分类号
摘要
A dispenser cathode life model (DCLM) was originally published in 1984. More recent life test data have substantiated the basic physics used in the DCLM. However, re-evaluation of the model with this latest data alters the numerical parameters used in the model. The most important modification is the incorporation of the shape factor, alpha, in the emission equation, so that accurate descriptions of the cathode activity curves (i.e., current versus temperature) can be made as a function of cathode age. The original model was fit only to the cathode current as a function of time for a fixed operating temperature. This revision fits the cathode activity curves as a function of both time and cathode temperature. Variation in cathode current as a function of temperature is quite dependent upon the underlying physics, and gives a better measure of how the internal parameters, such as work function and knee position and knee shape change with time. Knowing these details provides a more accurate measure of how the cathode current at the operating point will change over time. The modification made to the emission equation in this revision incorporates the shape factor, alpha, which is a single number that describes the shape of the cathode activity curves. The shape factor is found to be dependent on time: The knee softens and rounds with age. Even though the shape factor was originally introduced as an empirical factor, I will present a theoretical model for the shape factor that provides some insight into its physical interpretation. This theory will show that it can be related to the thermodynamics of the emitter surface. The re-evaluation of the DCLM, based on the latest life data, and including the theory for the shape factor yields a longer life expectancy for the M-type dispenser cathode then was predicted by the original more conservative life model. The DCLM matches the observed life data more accurately. (C) 2003 American Institute of Physics.
引用
收藏
页码:6966 / 6975
页数:10
相关论文
共 24 条
[1]  
ADAMSON AW, 1982, PHYSICAL CHEM SURFAC
[2]  
[Anonymous], 1949, Scientific Foundations of Vacuum Technique
[3]  
BRODIE I, 1959, J ELECTRON CONTR, V6, P149
[4]   Discharge from hot CaO. [J].
Child, CD .
PHYSICAL REVIEW, 1911, 32 (05) :0492-0511
[5]  
COPPOLA PP, 1957, PHILIPS TECH REV, V19, P179
[6]  
FALCE L, 1978, Patent No. 4165773
[7]  
FALCE LR, 1984, INT EL DEV M 1984, P318
[8]   WORK FUNCTION VARIATION OF METALS COATED BY METALLIC FILMS [J].
GYFTOPOULOS, EP ;
LEVINE, JD .
JOURNAL OF APPLIED PHYSICS, 1962, 33 (01) :67-&
[9]  
Huang K., 1963, Statistical Mechanics
[10]  
LANGMUIR I, 1921, PHYS REV, V17, P441